<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-09-22T05:58:36Z</responseDate>
  <request verb="GetRecord" identifier="oai:salford-repository.worktribe.com:1366469" metadataPrefix="uketd_dc">salford-repository.worktribe.com</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:salford-repository.worktribe.com:1366469</identifier>
        <datestamp>2026-06-07T06:48:43Z</datestamp>
        <setSpec>084104101115105115</setSpec>
        <setSpec>openaccess</setSpec>
      </header>
      <metadata>
        <uketd_dc:uketddc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:uketd_dc="http://naca.central.cranfield.ac.uk/ethos-oai/2.0/" xmlns:uketdterms="http://naca.central.cranfield.ac.uk/ethos-oai/terms/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:type>Thesis</dc:type>
          <dc:title>Establishing an evidence-base for erect pelvis radiography : positioning, radiation dose and image quality</dc:title>
          <dcterms:abstract>Purpose: Pelvic  radiography  using  X-ray  imaging  has  traditionally  been  used  for  the identification  of  hip  joint  changes,  including  the  identification  of  pathologies  such  as osteoarthritis. For patients suffering from hip pain, the supine pelvis X-ray examination is one of the initial diagnostic steps. Despite this, many recent studies have recommended that the  position  should  now  be  undertaken  erect  and  not  supine  to  reflect  the  functional appearances of the hip joint. This thesis aims to establish an evidence base for erect pelvis radiography, and it will include assessing radiographic positioning, radiation dose and image quality.  Methods:  The experimental work described in this thesis was conducted in three phases. Each phase has its own methods with the purpose of achieving a specific set of aims. Phase One was the evaluation of the postural effects of different erect (standing) positions in  order  to  recommend  an  optimal  one  for  erect  pelvic  radiography.  Eight  different  erect positions were investigated. A sample group of 67 healthy people participated, and a range of  spinal  and  pelvis  measurements  were  acquired  using  a  3D  video  rasterography  system (Diers) and an inclinometer.Phase  Two was  a  phantom  study  evaluating  the  potential  changes  to  radiation  dose  and image quality when moving between supine and erect imaging. Phase two was undertaken using three experiments (experiment #1, experiment #2 and experiment #3).  Experiment #1 evaluated the impact of increased patient size on  the radiation dose and image quality.  In this experiment, animal fat was positioned anteriorly on a pelvic anthropomorphic phantom and the thickness increased incrementally in 1cm steps from 1 to 15cm. Image quality was evaluated  physically  and  visually. The  effective  dose  was  calculated using  Monte  Carlo simulation  software  (PCXMC). During  experiment  #2,  the  anterior  thicknesses  for  109 patients, with a range of BMIs, who were referred for pelvis radiography, was measured in the erect and supine position. Experiment #3 evaluated the potential differences between the positions  (supine and  erect)  in  terms  of  image  quality  and  radiation  dose  by  modelling patient thickness changes between positions using the data obtained in experiment #2. An anthropomorphic  phantom  was  used  and  modified  (by adding  additional  fat)  to  simulate tissue changes for both erect and supine X-ray positions. Visual grading analysis was used (VGA)  to  evaluate  image  quality.  The  effective  dose  and  absorbed  dose  were  calculated using PCXMC.During Phase  Three,  60  patients  were  imaged  in  erect  and  supine  positions.  The paired pelvis  X-ray  images  were  then  compared,  taking  into  account  radiation  dose  and  image quality.Results: Phase  One demonstrated  no  statistical  differences  between  the  eight-different standing  positions  for  pelvic  and  spine  metrics  (P&gt;0.05).  Results also  demonstrated  no significant postural differences between BMIs across all eight standing positions (P&gt;0.05). Also,  no  differences  (P&gt;0.05)  were  identified  in  the  pelvis  and  spinal  metrics  when comparing between males and females .Standing relaxed with feet internally rotated by 20°and the upper arms supported was a recommendation derived from this phase. Results  from Phase  Two showed  an  increase  in  effective  dose  (E)  as  the  fat  thickness increased.  Also, all  physical  and  visual  image  quality  metrics  decreased  as  fat  thickness increased. Physical and visual image quality measures also decreased for erect images when compared to supine images, and the E also increased. 90kVp, 130/145 SID, using both outer chambers,  were  the  recommended  exposure  parameters  settings  for  obtaining  erect  pelvis X-ray images. Results from Phase Three showed that anterior patient thickness was 17% (P&lt;0.001) higher in an erect position .The DAP and absorbed dose were 46% and 45% (P&lt;0.001) greater in the erect position. Also, the effective dose was 67% (P&lt;0.001) higher in the erect position when compared with supine. In regard to the image quality (IQ), that of the erect position decreased by 10% when compared with supine (P&lt;0.001).Conclusion: The eight proposed standing positions could theoretically be suitable for erect pelvis imaging. People in a relaxed standing position, with their feet internally rotated by 20°and their upper arms supported would be recommended.  In terms of  IQ and radiation dose for erect positions, this position decreases image quality (both physical and visual) and increased radiation dose. Changes were largely due to the effect of gravity on the anterior soft tissue distribution. These issues should be considered and optimised more fully when deciding if to move from supine to erect pelvis imaging.</dcterms:abstract>
          <dc:creator>Alzyoud, K</dc:creator>
          <uketdterms:qualificationlevel>Doctoral (Level 8)</uketdterms:qualificationlevel>
          <dcterms:dateAccepted>2026-09-22</dcterms:dateAccepted>
          <dc:identifier>oai:salford-repository.worktribe.com:1366469</dc:identifier>
          <dc:identifier xsi:type="dcterms:URI">https://salford-repository.worktribe.com/file/1366469/1/kholoud%20thesis2%20after%20correction.pdf</dc:identifier>
          <uketdterms:sponsor>#1 FUNDER NOT LISTED</uketdterms:sponsor>
          <dcterms:isReferencedBy>https://salford-repository.worktribe.com/output/1366469</dcterms:isReferencedBy>
          <dcterms:issued>2026</dcterms:issued>
          <dc:language>en</dc:language>
          <dc:licence>openAccess</dc:licence>
          <dcterms:accessRights>Public</dcterms:accessRights>
        </uketd_dc:uketddc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
