Neonatal chest radiography : influence of standard clinical protocols and radiographic equipment on pathology visibility and radiation dose using a neonatal chest phantom (2020)
Journal Article
Al-Murshedi, S., Hogg, P., & England, A. (2020). Neonatal chest radiography : influence of standard clinical protocols and radiographic equipment on pathology visibility and radiation dose using a neonatal chest phantom. Radiography, 26(4), 282-287. https://doi.org/10.1016/j.radi.2020.02.005

Introduction: Little is known about the variations in pathology visibility (PV) and their corresponding radiation dose values for neonatal chest radiography, between and within hospitals. Large variations in PV could influence the diagnostic outcome... Read More about Neonatal chest radiography : influence of standard clinical protocols and radiographic equipment on pathology visibility and radiation dose using a neonatal chest phantom.

Can the anode heel effect be used to optimise radiation dose and image quality for AP pelvis radiography? (2019)
Journal Article
Mraity, H., England, A., Lanca, L., Hogg, P., Walton, L., & Thompson, J. (2020). Can the anode heel effect be used to optimise radiation dose and image quality for AP pelvis radiography?. Radiography, 26(2), e103-e108. https://doi.org/10.1016/j.radi.2019.11.094

Introduction:

A study was conducted to determine whether the anode heel effect can be used to influence optimisation of radiation dose and image quality (IQ) for AP pelvis radiography.

Methods:

ATOM dosimetry phantom and an anthropomorp... Read More about Can the anode heel effect be used to optimise radiation dose and image quality for AP pelvis radiography?.

Development and validation of a bespoke phantom to test accuracy of Cobb angle measurements (2019)
Journal Article
Alrehily, F., Hogg, P., Twiste, M., Johansen, S., & Tootell, A. (2020). Development and validation of a bespoke phantom to test accuracy of Cobb angle measurements. Radiography, 26(2), e78-e87. https://doi.org/10.1016/j.radi.2019.11.002

Introduction: Adolescent idiopathic scoliosis (AIS) is a spinal deformity that causes the spine to bend laterally. Patients with AIS undergo frequent X-ray examinations to monitor the progression of the disorder by through the measurement of the Cobb... Read More about Development and validation of a bespoke phantom to test accuracy of Cobb angle measurements.

The accuracy of Cobb angle measurement on CT scan projection radiograph images (2019)
Journal Article
Alrehily, F., Hogg, P., Twiste, M., Johansen, S., & Tootell, A. (2020). The accuracy of Cobb angle measurement on CT scan projection radiograph images. Radiography, 26(2), e73-e77. https://doi.org/10.1016/j.radi.2019.11.001

Introduction: Adolescent idiopathic scoliosis (AIS) is a spinal deformity that can affect young children. It requires frequent exposure to X-rays to monitor the deformity, which can lead to the development of radiation-induced cancer later in life. T... Read More about The accuracy of Cobb angle measurement on CT scan projection radiograph images.

Dose optimisation in paediatric radiography - using regression models to investigate the relative impact of acquisition factors on image quality and radiation dose (2019)
Journal Article
Ali, M., Hogg, P., & England, A. (2019). Dose optimisation in paediatric radiography - using regression models to investigate the relative impact of acquisition factors on image quality and radiation dose. Physica Medica, 68, 61-68. https://doi.org/10.1016/j.ejmp.2019.10.034

Objective: To investigate the optimum pelvis X-ray acquisition factors for a 10-year-old child. Secondly, to evaluate the impact of each acquisition factor on image quality (IQ) and radiation dose.

Method: Images were acquired using a pelvis phan... Read More about Dose optimisation in paediatric radiography - using regression models to investigate the relative impact of acquisition factors on image quality and radiation dose.

Investigating the ability to use the CT scan projection radiograph to monitor adolescent idiopathic scoliosis (2019)
Thesis
Alrehily, F. Investigating the ability to use the CT scan projection radiograph to monitor adolescent idiopathic scoliosis. (Thesis). University of Salford

Introduction: Adolescent idiopathic scoliosis (AIS) is a spinal deformity that causes the spine to bend laterally. Patients with AIS undergo frequent X-ray examinations to monitor the progression of the deformity through the measurement of the Cobb a... Read More about Investigating the ability to use the CT scan projection radiograph to monitor adolescent idiopathic scoliosis.

Radiographers’ perspectives’ on visual grading analysis as a scientific method to evaluate image quality (2019)
Journal Article
Precht, H., Hansson, J., Outzen, C., Hogg, P., & Tingberg, A. (2019). Radiographers’ perspectives’ on visual grading analysis as a scientific method to evaluate image quality. Radiography, 25(Sup. 1), S14-S18. https://doi.org/10.1016/j.radi.2019.06.006

Introduction

Radiographers routinely undertake many initiatives to balance image quality with radiation dose (optimisation). For optimisation studies to be successful image quality needs to be carefully evaluated. Purpose was to 1) discuss the st... Read More about Radiographers’ perspectives’ on visual grading analysis as a scientific method to evaluate image quality.

Impact of acquisition parameters on dose and image quality optimisation in paediatric pelvis radiography - a phantom study (2019)
Journal Article
Mohammed Ali, A., Hogg, P., & England, A. (2019). Impact of acquisition parameters on dose and image quality optimisation in paediatric pelvis radiography - a phantom study. European Journal of Radiology, 118, 130-137. https://doi.org/10.1016/j.ejrad.2019.07.014

Purpose: Within paediatric pelvis imaging there is a lack of systematic dose optimisation studies which consider age and size variations. This paper presents data from dose optimisation studies using digital radiography and pelvis phantoms representi... Read More about Impact of acquisition parameters on dose and image quality optimisation in paediatric pelvis radiography - a phantom study.

Video Rasterstereography of the spine and pelvis in eight erect positions : a reliability study (2019)
Journal Article
Alzyoud, K., Hogg, P., Snaith, B., Preece, S., & England, A. (2020). Video Rasterstereography of the spine and pelvis in eight erect positions : a reliability study. Radiography, 26(1), e7-e13. https://doi.org/10.1016/j.radi.2019.06.002

Introduction
To investigate the reliability and variability of Video Rasterstereography (VR) measurements of the spine and pelvis, for eight proposed standing postures, in order to help define an optimal standing position for erect pelvis radiogr... Read More about Video Rasterstereography of the spine and pelvis in eight erect positions : a reliability study.

Impact of contralateral breast shielding on the risk of developing radiation-induced cancer from full-field digital mammography screening (2019)
Journal Article
Ali, R., England, A., Mercer, C., Tootell, A., & Hogg, P. (2019). Impact of contralateral breast shielding on the risk of developing radiation-induced cancer from full-field digital mammography screening. Journal of Medical Imaging and Radiation Sciences, 50(2), 331-336. https://doi.org/10.1016/j.jmir.2019.02.005

Objective

The objective of this study was to investigate the impact of contralateral breast shielding on the risk of developing radiation-induced cancer from four-view full-field digital mammography (FFDM) screening.
Methods

A poly methyl meth... Read More about Impact of contralateral breast shielding on the risk of developing radiation-induced cancer from full-field digital mammography screening.

Radiation protection value to the operator from augmented reality smart glasses in interventional fluoroscopy procedures using phantoms (2019)
Journal Article
Dorey, S., Gray, L., Tootell, A., Higgins, R., Al-Islam, S., Baxter, H., …Hogg, P. (2019). Radiation protection value to the operator from augmented reality smart glasses in interventional fluoroscopy procedures using phantoms. Radiography, 25(4), 301-307. https://doi.org/10.1016/j.radi.2019.02.008

Introduction: Smart glasses can be adapted to display radiographic images to allow clinician’s gaze not to be directionally fixed or predetermined by computer monitor location. This study presents an analysis of eye lens dose during interventional fl... Read More about Radiation protection value to the operator from augmented reality smart glasses in interventional fluoroscopy procedures using phantoms.

Scoliosis imaging : an analysis of radiation risk in the CT scan projection radiograph and a comparison with projection radiography and EOS (2019)
Journal Article
Alrehily, F., Hogg, P., Twiste, M., Johansen, S., & Tootell, A. (2019). Scoliosis imaging : an analysis of radiation risk in the CT scan projection radiograph and a comparison with projection radiography and EOS. Radiography, 25(3), https://doi.org/10.1016/j.radi.2019.02.005

Introduction: Scoliosis is defined as a deformity of the spine with lateral curvature in the coronal plane. It requires regular X-ray imaging to monitor the progress of the disorder, therefore scoliotic patients are frequently exposed to radiation. I... Read More about Scoliosis imaging : an analysis of radiation risk in the CT scan projection radiograph and a comparison with projection radiography and EOS.

Comparative analysis of radiation dose and low contrast detail detectability using routine paediatric chest radiography protocols (2019)
Journal Article
Al-Murshedi, S., Hogg, P., Meijer, A., Erenstein, H., & England, A. (2019). Comparative analysis of radiation dose and low contrast detail detectability using routine paediatric chest radiography protocols. European Journal of Radiology, 113(Apr 19), 198-203. https://doi.org/10.1016/j.ejrad.2019.02.017

Objectives: To compare low contrast detail (LCD) detectability and radiation dose for routine paediatric chest X-ray (CXR) imaging protocols among various hospitals.

Methods: CDRAD 2.0 phantom and medical grade polymethyl methacrylate (PMMA) sl... Read More about Comparative analysis of radiation dose and low contrast detail detectability using routine paediatric chest radiography protocols.

OPTIMAX 2018 - a focus on education in radiology (2019)
Book
(2019). A. van der Heij-Meijer, C. Buissink, & P. Hogg (Eds.), OPTIMAX 2018 - a focus on education in radiology. Greater Manchester, UK: University of Salford

This year, OPTIMAX was warmly welcomed by
University College Dublin. For the sixth time
students and teachers from Europe, South Africa,
South America and Canada have come together
enthusiastically to do research in the Radiography
domain. As in... Read More about OPTIMAX 2018 - a focus on education in radiology.

Relationship between body habitus and image quality and radiation dose in chest x-ray examinations : a phantom study (2018)
Journal Article
Al-Murshedi, S., Hogg, P., & England, A. (2019). Relationship between body habitus and image quality and radiation dose in chest x-ray examinations : a phantom study. Physica Medica, 57(Jan 19), 65-71. https://doi.org/10.1016/j.ejmp.2018.12.009

Purpose: To evaluate the influence of being overweight on image
quality (IQ), radiation dose and acquisition parameters when undertaking
adult chest x-ray (CXR) examinations using routine acquisition protocols.
Methods: The Lungman chest phantom... Read More about Relationship between body habitus and image quality and radiation dose in chest x-ray examinations : a phantom study.

ROI-based reversible watermarking scheme for ensuring the integrity and authenticity of DICOM MR images (2018)
Journal Article
Qasim, A., Aspin, R., Meziane, F., & Hogg, P. (2019). ROI-based reversible watermarking scheme for ensuring the integrity and authenticity of DICOM MR images. Multimedia Tools and Applications, 78(12), 16433-16463. https://doi.org/10.1007/s11042-018-7029-7

Reversible and imperceptible watermarking is recognized as a robust approach to confirm the integrity and authenticity of medical images and to verify that alterations can be detected and tracked back. In this paper, a novel blind reversible watermar... Read More about ROI-based reversible watermarking scheme for ensuring the integrity and authenticity of DICOM MR images.

Assessment of perceptual distortion boundary through applying reversible watermarking to brain MR images (2018)
Journal Article
Qasim, A., Aspin, R., Meziane, F., & Hogg, P. (2019). Assessment of perceptual distortion boundary through applying reversible watermarking to brain MR images. Signal Processing: Image Communication, 70, 246-258. https://doi.org/10.1016/j.image.2018.10.007

The digital medical workflow faces many circumstances in which the images can be manipulated during viewing, extracting and exchanging. Reversible and imperceptible watermarking approaches have the potential to enhance trust within the medical imagin... Read More about Assessment of perceptual distortion boundary through applying reversible watermarking to brain MR images.

Impact of body part thickness on AP pelvis radiographic image quality and effective dose (2018)
Journal Article
Alzyoud, K., Hogg, P., & England, A. (2019). Impact of body part thickness on AP pelvis radiographic image quality and effective dose. Radiography, 25(1), e11-e17. https://doi.org/10.1016/j.radi.2018.09.001

Introduction: Within medical imaging variations in patient size can generate challenges, especially when selecting appropriate acquisition parameters. This experiment sought to evaluate the impact of increasing body part thickness on image quality (... Read More about Impact of body part thickness on AP pelvis radiographic image quality and effective dose.