Breast compression - an exploration of problem solving and decision making in mammography (2014)
Journal Article
Nightingale, J., Murphy, F., Robinson, L., Newton-Hughes, A., & Hogg, P. (2015). Breast compression - an exploration of problem solving and decision making in mammography. Radiography, 21(4), 364-369. https://doi.org/10.1016/j.radi.2014.11.004

Objective: Breast compression decreases radiation dose and reduces potential for motion and geometric unsharpness, yet there is variability in applied compression force within and between some centres. This article explores the problem solving proces... Read More about Breast compression - an exploration of problem solving and decision making in mammography.

Extra patient movement during mammographic imaging : an experimental study (2014)
Journal Article
an experimental study. British Journal of Radiology, 87(1044), https://doi.org/10.1259/bjr.20140241

Objectives: To determine if movement external to the patient occurring during mammography may be a source of image blur. Methods: Four mammography machines with seven flexible and nine fixed paddles were evaluated. In the first stage, movement at the... Read More about Extra patient movement during mammographic imaging : an experimental study.

The influence of experience and training in a group of novice observers : A jackknife alternative free-response receiver operating characteristic analysis (2014)
Journal Article
observers : A jackknife alternative free-response receiver operating characteristic analysis. Radiography, 20(4), 300-305. https://doi.org/10.1016/j.radi.2014.06.016

Purpose: The study evaluates the pre- and post-training lesion localisation ability of a group of novice
observers. Parallels are drawn with the performance of inexperienced radiographers taking part in
preliminary clinical evaluation (PCE) and β€˜re... Read More about The influence of experience and training in a group of novice observers : A jackknife alternative free-response receiver operating characteristic analysis.

An evaluation of the student and tutor experience of a residential summer school event (OPTIMAX) (2014)
Journal Article
Higgins, R., Robinson, L., & Hogg, P. (2014). An evaluation of the student and tutor experience of a residential summer school event (OPTIMAX). Radiography, 20(4), 363-368. https://doi.org/10.1016/j.radi.2014.06.015

Aim: To explore the experiences of students and tutors who participated in a residential multi-cultural and multi-professional 3 week summer school event (OPTIMAX).

Method: A grounded theory approach was adopted. Two semi-structured focus group in... Read More about An evaluation of the student and tutor experience of a residential summer school event (OPTIMAX).

Increasing source to image distance for AP pelvis imaging – impact on radiation dose and image quality (2014)
Journal Article
Tugwell, E., Everton, C., Kingma, A., & Hogg, P. (2014). Increasing source to image distance for AP pelvis imaging – impact on radiation dose and image quality. Radiography, 20(4), 351-355. https://doi.org/10.1016/j.radi.2014.05.012

Aim: A quantative primary study to determine whether increasing source to image distance (SID), with
and without the use of automatic exposure control (AEC) for antero-posterior (AP) pelvis imaging, reduces
dose whilst still producing an image of d... Read More about Increasing source to image distance for AP pelvis imaging – impact on radiation dose and image quality.

Analysing data from observer studies in medical imaging research : An introductory guide to free-response techniques (2014)
Journal Article
Thompson, J., Manning, D., & Hogg, P. (2014). Analysing data from observer studies in medical imaging research : An introductory guide to free-response techniques. Radiography, 20(4), 295-299. https://doi.org/10.1016/j.radi.2014.04.005

Observer performance methods maintain their place in radiology research, particularly in the assessment
of the diagnostic accuracy of new and existing techniques, despite not being fully embraced by the wider
audience in medical imaging. The receiv... Read More about Analysing data from observer studies in medical imaging research : An introductory guide to free-response techniques.

10 kVp rule - an anthropomorphic pelvis phantom imaging study using a CR system : impact on image quality and effective dose using AEC and manual mode (2014)
Journal Article
Lanca, L., Franco, L., Ahmed, A., & Hogg, P. (2014). 10 kVp rule - an anthropomorphic pelvis phantom imaging study using a CR system : impact on image quality and effective dose using AEC and manual mode. Radiography, 20(4), 333-338. https://doi.org/10.1016/j.radi.2014.04.007

Purpose: This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system.
M... Read More about 10 kVp rule - an anthropomorphic pelvis phantom imaging study using a CR system : impact on image quality and effective dose using AEC and manual mode.

Effects of kilovoltage, milliampere seconds, and focal spot size on image quality (2014)
Journal Article
Ma, W., Norton, S., & Hogg, P. (2014). Effects of kilovoltage, milliampere seconds, and focal spot size on image quality. Radiologic technology, 85(5), 479-485

Purpose To determine how kilovoltage (kV), milliampere seconds (mAs), and focal spot size affect perceptual image quality
using a hand phantom.
Methods Using computed radiography, 70 images of a posteroanterior (PA) oblique hand phantom were acquir... Read More about Effects of kilovoltage, milliampere seconds, and focal spot size on image quality.

A free-response evaluation determining value in the computed tomography attenuation correction image for revealing pulmonary incidental findings : a phantom study (2014)
Journal Article
Thompson, J., Hogg, P., Manning, D., Szczepura, K., & Chakraborty, D. (2014). A free-response evaluation determining value in the computed tomography attenuation correction image for revealing pulmonary incidental findings : a phantom study. Academic radiology, 21(4), 538-545. https://doi.org/10.1016/j.acra.2014.01.003

RATIONALE AND OBJECTIVES: The purpose of this study was to compare lesion-detection performance when interpreting computed tomography (CT) images that are acquired for attenuation correction when performing single photon emission computed tomography/... Read More about A free-response evaluation determining value in the computed tomography attenuation correction image for revealing pulmonary incidental findings : a phantom study.

Integrating research-informed teaching within an undergraduate diagnostic radiography curriculum : Results from a level 4 (year 1) student cohort (2014)
Journal Article
Higgins, R., Robinson, L., & Hogg, P. (2014). Integrating research-informed teaching within an undergraduate diagnostic radiography curriculum : Results from a level 4 (year 1) student cohort. Radiography, 20(2), 100-106. https://doi.org/10.1016/j.radi.2014.02.002

Aim
Previously we reported on focus group research which explored the level 4 (year 1) student experience of the Research-informed Teaching experience (RiTe). This article discusses follow up research with a new student cohort.

Method
An online... Read More about Integrating research-informed teaching within an undergraduate diagnostic radiography curriculum : Results from a level 4 (year 1) student cohort.

A systematic procedure to optimise dose and image quality for the measurement of inter-vertebral angles from lateral spinal projections using Cobb and superimposition methods (2014)
Journal Article
Al Qaroot, B., Hogg, P., Twiste, M., & Howard, D. (2014). A systematic procedure to optimise dose and image quality for the measurement of inter-vertebral angles from lateral spinal projections using Cobb and superimposition methods. Journal of X-Ray Science and Technology, 22(5), 613-625. https://doi.org/10.3233/XST-140449

BACKGROUND: Patients with vertebral column deformations are exposed to high risks associated with ionising radiation exposure. Risks are further increased due to the serial X-ray images that are needed to measure and asses their spinal deformation us... Read More about A systematic procedure to optimise dose and image quality for the measurement of inter-vertebral angles from lateral spinal projections using Cobb and superimposition methods.