Predictors of radiation dose for uterine artery embolisation are angiography system-dependent

Nocum, D; Robinson, J; Halaki, M; Båth, M; Thompson, JD; Thompson, N; Moscova, M; Liang, E; Mekiš, N; Reed, W

Predictors of radiation dose for uterine artery embolisation are angiography system-dependent Thumbnail


Authors

D Nocum

J Robinson

M Halaki

M Båth

JD Thompson

N Thompson

M Moscova

E Liang

N Mekiš

W Reed



Abstract

This study sought to achieve radiation dose reductions for patients receiving uterine artery embolisation (UAE) by evaluating radiation dose measurements for the preceding generation (Allura) and upgraded (Azurion) angiography system. Previous UAE regression models in the literature could not be applied to this centre’s practice due to being based on different angiography systems and radiation dose predictor variables. The aims of this study were to establish whether radiation dose is reduced with the upgraded angiography system and to develop a regression model to determine predictors of radiation dose specific to the upgraded angiography system. A comparison between Group I (Allura, n = 95) and Group II (Azurion, n = 95) demonstrated a significant reduction in KAP (kerma-area product) and Ka, r (reference air kerma) by 63% (143.2 Gy·cm2 vs 52.9 Gy·cm2; P < 0.001, d = 0.8) and 67% (0.6 Gy vs 0.2 Gy; P < 0.001, d = 0.8), respectively. The multivariable linear regression (MLR) model identified the UAE radiation dose predictors for KAP on the upgraded angiography system as total fluoroscopy dose, Ka, r, and total uterus volume. The predictive accuracy of the MLR model was assessed using a Bland-Altman plot. The mean difference was 0.39 Gy·cm2 and the limits of agreement (LoA) were +28.49 and -27.71 Gy·cm2, and thus illustrated no proportional bias. The resultant MLR model was considered system-dependent and validated the upgraded angiography system and its advance capabilities to significantly reduce radiation dose. Interventional radiologist and interventional radiographer familiarisation of the system’s features and the implementation of the newly established MLR model would further facilitate dose optimisation for all centres performing UAE procedures using the upgraded angiography system.

Citation

Nocum, D., Robinson, J., Halaki, M., Båth, M., Thompson, J., Thompson, N., …Reed, W. (2022). Predictors of radiation dose for uterine artery embolisation are angiography system-dependent. Journal of Radiological Protection, 42(1), 011502. https://doi.org/10.1088/1361-6498/ac480b

Journal Article Type Article
Acceptance Date Jan 4, 2022
Online Publication Date Jan 17, 2022
Publication Date Mar 1, 2022
Deposit Date Jan 6, 2022
Publicly Available Date Jan 17, 2023
Journal Journal of Radiological Protection
Print ISSN 0952-4746
Electronic ISSN 1361-6498
Publisher IOP Publishing
Volume 42
Issue 1
Pages 011502
DOI https://doi.org/10.1088/1361-6498/ac480b
Publisher URL https://doi.org/10.1088/1361-6498/ac480b
Related Public URLs http://iopscience.iop.org/0952-4746

Files

PAPER 4 -JT suggestions_DN_11.12.21_JT_13.12.21_DN_14.12.21.pdf (427 Kb)
PDF






Downloadable Citations