Skip to main content

Research Repository

Advanced Search

Sensitivity analysis of biomechanical effect in vertebral body of two different augmenters

Yuewan, S; Dongmei, W; Wei, W; Jingchuan, S; Liu, A; Jiangang, S

Authors

S Yuewan

W Dongmei

W Wei

S Jingchuan

S Jiangang



Abstract

Transvertebral Bone Graft and Augmentation (TBGA) has achieved good clinical effects in the treatment of osteoporotic vertebral compression fractures (OVCFs). This study aimed to investigate the postoperatively biomechanical effects of TBGA and compare the biomechanical sensitivity of two different augmenters: a cylindrical enhancement device (CED) and bone cement. Finite element models of the spine segment T11-L3 were created, including one model based on normal segment and the other three with L1 augmentation for pathological conditions. Three treatments were simulated including CED implant treatment A, CED implant treatment B, and bone cement treatment. The stress distribution and maximum displacement of the four models under different treatments were analyzed. A method of linear fitting of dummy variables was used to analyze the sensitivity of biomechanical parameters to the degree of osteoporosis (DO) and load. The reduction of stress with increasing DO in augmented and adjacent vertebral bodies under bone cement augmentation was less than that under CED augmentation. The stress of augmented vertebral body and the adjacent vertebral body was most sensitive to extension and rotation loading conditions. As DO increasing, the bone cement augmentation significantly increased the stress level on the upper and lower endplates. When the degree of osteoporosis increased, CED outperforms bone cement in terms of the stress reduction in augmented vertebral and adjacent vertebral, which could be beneficial for avoiding re-fracture. Using TBGA to treat OVCFs, especially with Plan B method, the condition of the pathological spine is closer to the original status in terms of the sensitivity to stress and the spinal range of motion. The TBGA treatment is sensitive to lateral bending and torsion, therefore patients should be advised to avoid high-risk motions like lateral bending and rotation. [Abstract copyright: Copyright © 2020. Published by Elsevier Ltd.]

Citation

Yuewan, S., Dongmei, W., Wei, W., Jingchuan, S., Liu, A., & Jiangang, S. (2020). Sensitivity analysis of biomechanical effect in vertebral body of two different augmenters. Clinical Biomechanics, 80, 105166. https://doi.org/10.1016/j.clinbiomech.2020.105166

Journal Article Type Article
Acceptance Date Aug 28, 2020
Online Publication Date Sep 10, 2020
Publication Date Dec 1, 2020
Deposit Date Jan 4, 2021
Journal Clinical Biomechanics
Print ISSN 0268-0033
Electronic ISSN 1879-1271
Publisher Elsevier
Volume 80
Pages 105166
DOI https://doi.org/10.1016/j.clinbiomech.2020.105166
Publisher URL https://doi.org/10.1016/j.clinbiomech.2020.105166
Related Public URLs http://www.journals.elsevier.com/clinical-biomechanics/
Additional Information Additional Information : ** From PubMed via Jisc Publications Router **Journal IDs: eissn 1879-1271 **Article IDs: pubmed: 32928587; pii: S0268-0033(20)30285-0 **History: accepted 28-08-2020; revised 28-11-2019; submitted 26-02-2019
Funders : Scientific Research Topics of Shanghai Health and Family Planning Commission
Grant Number: 201640262