EA Gandy
Investigation of the use of inertial sensing equipment for the measurement of hip flexion and pelvic rotation in horse riders
Gandy, EA; Bondi, A; Pigott, TMC; Smith, G; McDonald, S
Abstract
Equestrian sports report three to five times higher incidence rates for lower back pain than that of the general population, with hip flexion angles of 50-60° suggested as a causal factor. Inertial motion capture technology enables dynamic measurement of rider kinematics but data extraction is time-consuming. The aim of this study was to develop a software tool to automate the process of extracting biomechanical data from the XsensTM MVN (MoCap) system to investigate postural changes in riders, comparing static position at halt with dynamic position during the sit phase of rising trot. The software was found to be efficient, reducing data extraction time by 97% when used with a sample of 16 riders. Good correlation was found between hip flexion and pelvic anterior-posterior rotation and between halt and trot but with significantly greater values of hip flexion and pelvic anterior rotation in trot. No riders showed hip flexion >50° at halt but 11 riders (69%) showed hip flexion >50° during the sit phase of rising trot, indicating that dynamic assessment is important when considering rider postural faults that may put them at risk of back injury.
Keywords: Hip flexion, Horse rider, Inertial sensor, Motion capture, Pelvic rotation
Citation
Gandy, E., Bondi, A., Pigott, T., Smith, G., & McDonald, S. (2018). Investigation of the use of inertial sensing equipment for the measurement of hip flexion and pelvic rotation in horse riders. Comparative Exercise Physiology, 14(2), 99-110. https://doi.org/10.3920/CEP170023
Journal Article Type | Article |
---|---|
Acceptance Date | Apr 1, 2018 |
Online Publication Date | Jun 7, 2018 |
Publication Date | Jun 7, 2018 |
Deposit Date | May 1, 2018 |
Publicly Available Date | Jun 12, 2018 |
Journal | Comparative Exercise Physiology |
Print ISSN | 1755-2540 |
Electronic ISSN | 1755-2559 |
Publisher | Wageningen Academic Publishers |
Volume | 14 |
Issue | 2 |
Pages | 99-110 |
DOI | https://doi.org/10.3920/CEP170023 |
Publisher URL | https://doi.org/10.3920/CEP170023 |
Related Public URLs | https://www.wageningenacademic.com/loi/cep |
Additional Information | Access Information : The official version of record of this paper is available at the official URL link above. |
Files
Measurement of hip flexion and pelvic rotation in horse riders using IMUs.pdf
(362 Kb)
PDF
Version
Authors' accepted manuscript
You might also like
Cauda Equina screening in physiotherapy : are we asking the right questions and are we asking the questions right?
(2022)
Presentation / Conference Contribution
Downloadable Citations
About USIR
Administrator e-mail: library-research@salford.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search