Digital Mammography: A Holistic Approach (2022)
Book
Mercer, C., Hogg, P., & Kelly, J. (2022). Digital Mammography: A Holistic Approach. Springer Cham. https://doi.org/10.1007/978-3-031-10898-3

This heavily revised second edition is a practically focused textbook focusing on how to successfully utilise mammography-related techniques. It covers a wide range of topics related to holistic mammographic imaging reflecting the emerging digital an... Read More about Digital Mammography: A Holistic Approach.

A comparative study of pain experienced during successive mammography examinations in patients with a family history of breast cancer and those who have had breast cancer surgery (2019)
Journal Article
cancer and those who have had breast cancer surgery. Radiography, 26(1), 76-81. https://doi.org/10.1016/j.radi.2019.08.007

INTRODUCTION: To measure mammography-related pain in two groups of women undergoing regular surveillance as a baseline for future care. METHODS: Following ethical approval, two hundred women aged 32 to 84 years (mean 54), were invited by written inv... Read More about A comparative study of pain experienced during successive mammography examinations in patients with a family history of breast cancer and those who have had breast cancer surgery.

Learning to look : evaluating the student experience of an interactive image appraisal activity (2019)
Journal Article
Ashworth, J., Thompson, J., & Mercer, C. (2019). Learning to look : evaluating the student experience of an interactive image appraisal activity. Radiography, 25(4), 314-319. https://doi.org/10.1016/j.radi.2019.02.011

Introduction: Student radiographers have expressed difficulty in performing image appraisal tasks. The purpose of this study was to investigate the value of a workshop delivered to level 4 undergraduate students. All students completed an image appra... Read More about Learning to look : evaluating the student experience of an interactive image appraisal activity.

Calculating individual lifetime effective risk from initial mean glandular dose arising from the first screening mammogram (2018)
Journal Article
Ali, R., England, A., Mercer, C., & Hogg, P. (2018). Calculating individual lifetime effective risk from initial mean glandular dose arising from the first screening mammogram. Journal of Medical Imaging and Radiation Sciences, 49(4), 406-413. https://doi.org/10.1016/j.jmir.2018.06.005

Objectives: To use the initial mean glandular dose (MGD) arising from the first screening mammogram to estimate the individual total screening lifetime effective risk. Methods: Organ doses from FFDM screening exposures (craniocaudal and mediolatera... Read More about Calculating individual lifetime effective risk from initial mean glandular dose arising from the first screening mammogram.

Malignant breast masses-conspicuity analysis in motionsimulated mammograms (2018)
Presentation / Conference
mammograms. Poster presented at The 2018 European Congress of Radiology (ECR), Vienna

The conspicuity of a mass represents a ratio between the contrast of a mass and its surrounding complexity. Measuring the conspicuity of lesions attempts to characterise the visibility of a lesion in terms of the imaging systems diagnostic capabiliti... Read More about Malignant breast masses-conspicuity analysis in motionsimulated mammograms.

An exploration of mammographers’ attitudes towards the use of social media for providing breast screening information to clients (2017)
Journal Article
Scragg, B., Shaikh, S., Shires, G., Stein Hodgins, J., Mercer, C., Robinson, L., & Wray, J. (2017). An exploration of mammographers’ attitudes towards the use of social media for providing breast screening information to clients. Radiography, 23(3), 249-255. https://doi.org/10.1016/j.radi.2017.04.004

Background: Increasingly patients and clients of health services are using social media to locate information about medical procedures and outcomes. There is increasing pressure for health professionals to engage in on-line spaces to provide clear a... Read More about An exploration of mammographers’ attitudes towards the use of social media for providing breast screening information to clients.

Mixed messages : an evaluation of NHS trust social media policies in the north west of England (2017)
Journal Article
Scragg, B., Shaikh, S., Robinson, L., & Mercer, C. (2017). Mixed messages : an evaluation of NHS trust social media policies in the north west of England. Radiography, 23(3), 235-241. https://doi.org/10.1016/j.radi.2017.03.018

Introduction: Despite National Health Service (NHS) information strategy promoting the use of Social Media (SoMe) to encourage greater engagement between service users and providers, a team investigating online SoMe interaction between breast screeni... Read More about Mixed messages : an evaluation of NHS trust social media policies in the north west of England.

Analysis of motion during the breast clamping phase of mammography (2016)
Journal Article
Ma, W., McEntee, M., Kelly, J., Millington, S., Mercer, C., & Hogg, P. (2016). Analysis of motion during the breast clamping phase of mammography. British Journal of Radiology, 89(1059), 20150715. https://doi.org/10.1259/bjr.20150715

Objectives: To measure paddle motion during the clamping phase of a breast phantom for a range of machine/paddle combinations. Methods: A deformable breast phantom was used to simulate a female breast. Twelve mammography machines from three manufa... Read More about Analysis of motion during the breast clamping phase of mammography.

Does elevating image receptor increase breast receptor footprint and improve pressure balance? (2015)
Journal Article
Smith, H., Szczepura, K., Mercer, C., Maxwell, A., & Hogg, P. (2015). Does elevating image receptor increase breast receptor footprint and improve pressure balance?. Radiography, 21(4), 359-363. https://doi.org/10.1016/j.radi.2015.02.001

There is no consensus in the literature regarding the image receptor (IR) position for the cradio-caudal projection in mammography. Some literature indicates the IR should be positioned to the infra mammary fold (IMF); other literature suggests the... Read More about Does elevating image receptor increase breast receptor footprint and improve pressure balance?.

A 6 year study of mammographic compression force : practitioner variability within and between screening sites (2014)
Journal Article
Mercer, C., Szczepura, K., Kelly, J., Millington, S., Denton, D., Borgen, R., …Hogg, P. (2015). A 6 year study of mammographic compression force : practitioner variability within and between screening sites. Radiography, 21(1), 68-73. https://doi.org/10.1016/j.radi.2014.07.004

Background The application of compression force in mammography is more heavily influenced by the practitioner rather than the client. This can affect client experience, radiation dose and image quality. This research investigates practitioner comp... Read More about A 6 year study of mammographic compression force : practitioner variability within and between screening sites.

A mammography image set for research purposes using BI-RADS density classification (2014)
Journal Article
Mercer, C., Hogg, P., Kelly, J., Borgan, R., Millington, S., Hilton, B., …Wheelan, P. (2014). A mammography image set for research purposes using BI-RADS density classification. Radiologic technology, 85(6), 609-613

Purpose Breast density categorization consistency is important when performing research, and minimization of interoperator and intraoperator variability is essential. This research aimed to validate a set of mammography images for visual breast den... Read More about A mammography image set for research purposes using BI-RADS density classification.

Does an increase in compression force really improve visual image quality in mammography? An initial investigation (2013)
Journal Article
Mercer, C., Hogg, P., Cassidy, S., & Denton, E. (2013). Does an increase in compression force really improve visual image quality in mammography? An initial investigation. Radiography, 19(4), 363-365. https://doi.org/10.1016/j.radi.2013.07.002

Objective: Literature speculates that visual image quality (IQ) and compression force levels may be directly related. This small study investigates whether a relationship exists between compression force levels and visual IQ. Method: To investiga... Read More about Does an increase in compression force really improve visual image quality in mammography? An initial investigation.

Practitioner compression force variation in mammography : a 6 year study (2013)
Journal Article
Mercer, C., Hogg, P., Szczepura, K., & Denton, E. (2013). Practitioner compression force variation in mammography : a 6 year study. Radiography, 19(3), 200-206. https://doi.org/10.1016/j.radi.2013.06.001

The application of breast compression in mammography may be more heavily influenced by the practitioner rather than the client. This could affect image quality and will affect client experience. This study builds on previous research to establish i... Read More about Practitioner compression force variation in mammography : a 6 year study.

Practitioner compression force variability in mammography : a preliminary study (2013)
Journal Article
Mercer, C., Hogg, P., Lawson, R., Diffey, J., & Denton, E. (2013). Practitioner compression force variability in mammography : a preliminary study. British Journal of Radiology, 86(1022), 1-9. https://doi.org/10.1259/bjr.20110596

Objective: This preliminary study determines whether the absolute amount of breast compression in mammography varies between and within practitioners. Methods: Ethics approval was granted. 488 clients met the inclusion criteria. Clients were im... Read More about Practitioner compression force variability in mammography : a preliminary study.

Pressure and breast thickness in mammography : an exploratory calibration study (2013)
Journal Article
Hogg, P., Taylor, M., Szczepura, K., Mercer, C., & Denton, E. (2013). Pressure and breast thickness in mammography : an exploratory calibration study. British Journal of Radiology, 86(1021), 1-7. https://doi.org/10.1259/bjr.20120222

Objective To perform a calibration study to provide data to help improve consistency in the pressure that is applied during mammography. Methods Automatic readouts of breast thickness accuracy vary between mammography machines; therefore, one m... Read More about Pressure and breast thickness in mammography : an exploratory calibration study.