BS EN 17887-1:2024 Thermal performance of buildings. In situ testing of completed buildings. Data collection for aggregate heat loss test (Part 1)
(2024)
Report
Fitton, R. (2024). BS EN 17887-1:2024 Thermal performance of buildings. In situ testing of completed buildings. Data collection for aggregate heat loss test (Part 1). London: BSI
Outputs (9)
BS EN 17887-2:2024 Thermal performance of buildings. In situ testing of completed buildings. Steady-state data analysis for aggregate heat loss test (2024)
Report
Fitton, R. (2024). BS EN 17887-2:2024 Thermal performance of buildings. In situ testing of completed buildings. Steady-state data analysis for aggregate heat loss test. London: BSI
BS EN 17888-1:2024 - Thermal performance of buildings. In situ testing of building test structures. Data collection for aggregate heat loss test (2024)
Report
Fitton, R., & BSI. (2024). BS EN 17888-1:2024 - Thermal performance of buildings. In situ testing of building test structures. Data collection for aggregate heat loss test. London: BSI
RICS Residential Retrofit Standard (2024)
Report
(2024). RICS Residential Retrofit Standard. London: RICSThe purpose of this professional standard is to: • establish a clear framework that sets minimum requirements to maintain consistent, high-quality standards for residential property retrofit advice in respect of provision of retrofit installation... Read More about RICS Residential Retrofit Standard.
Bellway Homes "The Future Home" Baseline Performance Report (2024)
Report
Fitton, R., Diaz, H., Farmer, D., Henshaw, G., Sitmalidis, A., & Swan, W. (2024). Bellway Homes "The Future Home" Baseline Performance Report. Salford: ERDF & Innovate UKThis report examines the fabric thermal performance of a prototype home (The Future Home, or TFH) built by Bellway Homes. The home was designed and built to meet the anticipated Future Homes Standard in terms of fabric performance. The research was c... Read More about Bellway Homes "The Future Home" Baseline Performance Report.
Saint Gobain & Barratt Developments “eHome2” Baseline Performance Report (2024)
Report
Fitton, R., Diaz Hernandez, H., Farmer, D., Henshaw, G., Sitmalidis, A., & Swan, W. (2024). Saint Gobain & Barratt Developments “eHome2” Baseline Performance Report. Salford: ERDF & Innovate UKThis report examines the fabric thermal performance of a prototype home (eHome2) built through a partnership with Saint Gobain and Barratt homes. The home was designed and built to meet the anticipated Future Homes Standard in terms of fabric perfor... Read More about Saint Gobain & Barratt Developments “eHome2” Baseline Performance Report.
Thermal insulation products for buildings - Factory made reflective insulation (RI) products - Specification (2023)
Report
Fitton, R., & British Standards Institution (BSI). (2023). Thermal insulation products for buildings - Factory made reflective insulation (RI) products - Specification. BSI
Building energy performance assessment based on in-situ measurements : challenges and general framework (2021)
Report
Fitton, R. (2021). Building energy performance assessment based on in-situ measurements : challenges and general frameworkSubtask 1 investigated the possibilities and limitations of common data bases and monitoring systems. This subtask is strongly related to subtasks 2 and 3 by linking the available input data – as much as possible based on existing (non-intrusive) mon... Read More about Building energy performance assessment based on in-situ measurements : challenges and general framework.
Testing of Stormguard secondary glazing film (2014)
Report
Fitton, R. (2014). Testing of Stormguard secondary glazing filmWe were asked to test this product in the Energy House over all of the windows in the house. The house currently has 5 main windows (windows to the front bay were not tested). The test consisted of two parts: a control test with no film on the window... Read More about Testing of Stormguard secondary glazing film.