Skip to main content

Research Repository

Advanced Search

The Reliability and Magnitude of Time-Dependent Force-Time Characteristics During the Isometric Midthigh Pull Are Affected by Both Testing Protocol and Analysis Choices

Guppy, Stuart N.; Kotani, Yosuke; Brady, Claire J.; Connolly, Shannon; Comfort, Paul; Haff, G. Gregory

Authors

Stuart N. Guppy

Yosuke Kotani

Claire J. Brady

Shannon Connolly

G. Gregory Haff



Abstract

Guppy, SN, Kotani, Y, Brady, CJ, Connolly, S, Comfort, P, and Haff, GG. Title: The reliability and magnitude of time-dependent force-time characteristics during the isometric mid-thigh pull are impacted by both testing protocol and analysis choices. J Strength Cond Res 36(5): 1191–1199, 2022—This study aimed to investigate whether the use of short-duration (SHORT) isometric midthigh pull (IMTP) trials resulted in greater reliability and magnitude of time-dependent force-time characteristics than traditionally performed IMTP trials (TRAD). Fourteen subjects with >6 months' training experience with the power clean volunteered to take part in the study. Subjects performed five ∼1-second IMTP trials (SHORT) and five 5-second IMTP trials (TRAD). SHORT resulted in substantially more reliable rate of force development (RFD) measures (intraclass correlation coefficient [ICC] = 0.97–0.99; coefficient of variation [CV] = 2.6–7.0%), particularly during time bands from force-onset to 150 ms, compared with TRAD when trials were selected for analysis based on peak force (ICC = 0.66–0.83; CV = 14.1–38.5%). Selecting TRAD trials based on RFD0-200 resulted in similar reliability compared with SHORT of those same epochs (ICC = 0.97–0.99; CV = 2.5–7.8%). Furthermore, SHORT resulted in significantly greater force at specific time points, RFD, and impulse compared with TRAD trials (p = 0.001–0.033; g = −0.16 to −0.66). Based on these results, strength and conditioning professionals should use specific testing protocols (i.e., TRAD and SHORT) depending on the component of an athlete's force-generating capacity that they wish to assess and remain aware of the effect analysis choices they have on the reliability of IMTP force-time characteristics.

Citation

Guppy, S. N., Kotani, Y., Brady, C. J., Connolly, S., Comfort, P., & Haff, G. G. (2022). The Reliability and Magnitude of Time-Dependent Force-Time Characteristics During the Isometric Midthigh Pull Are Affected by Both Testing Protocol and Analysis Choices. Journal of Strength and Conditioning Research, 36(5), 1191-1199. https://doi.org/10.1519/jsc.0000000000004229

Journal Article Type Article
Online Publication Date Feb 15, 2022
Publication Date Feb 15, 2022
Deposit Date Jul 29, 2022
Journal Journal of Strength and Conditioning Research
Print ISSN 1064-8011
Publisher Lippincott, Williams & Wilkins
Volume 36
Issue 5
Pages 1191-1199
DOI https://doi.org/10.1519/jsc.0000000000004229
Keywords Physical Therapy, Sports Therapy and Rehabilitation, Orthopedics and Sports Medicine, General Medicine
Publisher URL https://doi.org/10.1519/JSC.0000000000004229