Background: Owing to the viscoelastic nature of tendons it may be that the total excursion and hence strain experienced by the tendon under load may be affected by the duration of contraction. Here we examine the effect of contraction duration on the measured in vivo mechanical properties of the patellar tendon.
Methods: Nine healthy young men aged 21 (SEM 0.5 years) performed three short (3-4s) and three long (10-12s) maximal ramped isometric contractions on an isokinetic dynamometer, with real-time recordings of patellar excursions using B-mode ultrasonography synchronised with forces to determine tendon mechanical properties.
Findings: Maximal patellar excursion was approximately 42% (P<0.001, effect size (r)=0.9) lower for the short 3.6 (SEM 0.4mm) vs. the long 6.2 (SEM 0.4mm) contractions. Similarly, across the range of forces tested, strain was approximately 42% (P<0.001, r=0.9) lower for the short vs. the long contractions 4.5 (SEM 0.5) vs. 8.0 (SEM 0.9%), respectively. Tendon stiffness however, was approximately 77% greater (4648 SEM 434 vs. 2633 SEM 257 N mm(-1), P<0.001, r=0.9) for short vs. long contractions.
Interpretation: Contraction duration significantly affects tendon strain and associated measures of stiffness at all levels of force. The implications of this finding are twofold in that the results: (a) indicate that in order to compare tendon mechanical properties within or across studies, duration of contraction must be standardised and (b) have possible implications on training protocols and associated injury risks.
Citation
Pearson, S., Burgess, K., & Onambele, G. (2007). Creep and the in vivo assessment of human patellar tendon mechanical properties. Clinical Biomechanics, 22(6), 712-717. https://doi.org/10.1016/j.clinbiomech.2007.02.006
Journal Article Type | Article |
---|---|
Acceptance Date | Feb 20, 2007 |
Publication Date | Jul 1, 2007 |
Deposit Date | Jul 6, 2015 |
Journal | Clinical Biomechanics |
Print ISSN | 0268-0033 |
Publisher | Elsevier |
Peer Reviewed | Peer Reviewed |
Volume | 22 |
Issue | 6 |
Pages | 712-717 |
DOI | https://doi.org/10.1016/j.clinbiomech.2007.02.006 |
Publisher URL | http://dx.doi.org/10.1016/j.clinbiomech.2007.02.006 |
Related Public URLs | http://www.journals.elsevier.com/clinical-biomechanics/ |
You might also like
Reliability of human achilles tendon stiffness measures using freehand 3-D ultrasound
(2021)
Journal Article
Downloadable Citations
About USIR
Administrator e-mail: library-research@salford.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search