Skip to main content

Research Repository

Advanced Search

Multi-centre analysis of incidental findings on low-resolution CT attenuation correction images

Coward, J; Lawson, R; Kane, T; Elias, M; Howes, A; Birchall, J; Hogg, P

Multi-centre analysis of incidental findings on low-resolution CT attenuation correction images Thumbnail


Authors

J Coward

R Lawson

T Kane

M Elias

A Howes

J Birchall



Abstract

Objective: To review new incidental findings detected on
low-resolution CT attenuation correction (CTAC) images acquired
during single-photon emission CT (SPECT-CT) myocardial
perfusion imaging (MPI) and to determine whether
the CTAC images had diagnostic value and warrant reporting.

Methods: A multicentre study was performed in four UK
nuclear medicine departments. CTAC images acquired
as part of MPI performed using SPECT were evaluated to
identify incidental findings. New findings considered to
be clinically significant were evaluated further. Positive
predictive value (PPV) was determined at the time of
definitive diagnosis.

Results: Of 1819 patients studied, 497 (27.3%) had a
positive CTAC finding. 51 (2.8%) patients had findings
that were clinically significant at the time of the CTAC
report and had not been previously diagnosed. Only
four (0.2%) of these were potentially detrimental to
patient outcome.

Conclusion: One centre had a PPV of 0%, and the study
suggests that these CTAC images should not be reported.
Two centres with more modern equipment had low
PPVs of 0% and 6%, respectively, and further research is
suggested prior to drawing a conclusion. The centre with
best quality CT had a PPV of 67%, and the study suggests
that CTAC images from this equipment should be reported.
Advances in knowledge: This study is unique compared
with previous studies that have reported only the potential
to identify incidental findings on low-resolution CT images.
This study both identifies and evaluates new clinically
significant incidental findings, and it demonstrates that
the benefit of reporting the CTAC images depends on
the type of equipment used.

Citation

Coward, J., Lawson, R., Kane, T., Elias, M., Howes, A., Birchall, J., & Hogg, P. (2014). Multi-centre analysis of incidental findings on low-resolution CT attenuation correction images. British Journal of Radiology, 87(1042), https://doi.org/10.1259/bjr.20130701

Journal Article Type Article
Acceptance Date Aug 14, 2014
Online Publication Date Sep 16, 2014
Publication Date Sep 16, 2014
Deposit Date Sep 19, 2014
Publicly Available Date Oct 8, 2018
Journal British Journal of Radiology
Print ISSN 0007-1285
Electronic ISSN 1748-880X
Publisher British Institute of Radiology
Peer Reviewed Peer Reviewed
Volume 87
Issue 1042
DOI https://doi.org/10.1259/bjr.20130701
Publisher URL http://dx.doi.org/10.1259/bjr.20130701
Related Public URLs http://www.bir.org.uk/publications/journals/

Files






You might also like



Downloadable Citations