JD Thompson
A free-response evaluation determining value in the computed tomography attenuation correction image for revealing pulmonary incidental findings : a phantom study
Thompson, JD; Hogg, P; Manning, DJ; Szczepura, K; Chakraborty, D
Authors
Prof Peter Hogg P.Hogg@salford.ac.uk
DJ Manning
Ms Katy Szczepura K.Szczepura@salford.ac.uk
Associate Professor/Reader
D Chakraborty
Abstract
RATIONALE AND OBJECTIVES: The purpose of this study was to compare lesion-detection performance when interpreting computed tomography (CT) images that are acquired for attenuation correction when performing single photon emission computed tomography/computed tomography (SPECT/CT) myocardial perfusion studies. In the United Kingdom, there is a requirement that these images be interpreted; thus, it is necessary to understand observer performance on these images. MATERIALS AND METHODS: An anthropomorphic chest phantom with inserted spherical lesions of different sizes and contrasts was scanned on five different SPECT/CT systems using site-specific CT protocols for SPECT/CT myocardial perfusion imaging. Twenty-one observers (0-4years of CT experience) searched 26 image slices (17 abnormal, containing 1-3 lesions, and 9 normal, containing no lesions) for each CT acquisition. The observers marked and rated perceived lesions under the free-response paradigm. Four analyses were conducted using jackknife alternative free-response receiver operating characteristic (JAFROC) analysis: (1) 20-pixel acceptance radius (AR) with all 21 readers, abbreviated to 20/ALL analysis, (2) 40-pixel AR with 21 readers (40/ALL), (3) 20-pixel AR with 14 readers experienced in CT (20/EXP), and (4) 20-pixel AR with 7 readers with no CT experience (20/NOT). The significance level of the test was set so as to conservatively control the overall probability of a type I error to <0.05. RESULTS: The mean JAFROC figure of merit (FOM) for the five CT acquisitions for the 20/ALL study were 0.602, 0.639, 0.372, 0.475,and 0.719 with a significant difference in lesion-detection performance evident between all individual treatment pairs (P<.0001) with the exception of the 1-2 pairing, which was not significant (these differed only in milliamp seconds). System 5, which had the highest performance, had the smallest slice thickness and the largest matrix size. For the other analyses, the system orderings remained unchanged, and the significance of FOM difference findings remained identical to those for 20/ALL, with oneexception: for 20/EXP analysis the 1-2 difference became significant with the higher milliamp seconds superior. Improved detection performance was associated with a smaller slice thickness, increased matrix size, and, to a lesser extent, increased tube charge. CONCLUSIONS: Protocol variations for CT-based attenuation correction (AC) in SPECT/CT imaging have a measurable impact on lesion-detection performance. The results imply that z-axis resolution and matrix size had the greatest impact on lesion detection, with a weaker but detectable dependence on the product of milliamp and seconds.
Citation
Thompson, J., Hogg, P., Manning, D., Szczepura, K., & Chakraborty, D. (2014). A free-response evaluation determining value in the computed tomography attenuation correction image for revealing pulmonary incidental findings : a phantom study. Academic radiology, 21(4), 538-545. https://doi.org/10.1016/j.acra.2014.01.003
Journal Article Type | Article |
---|---|
Acceptance Date | Jan 8, 2014 |
Online Publication Date | Mar 1, 2014 |
Publication Date | Apr 1, 2014 |
Deposit Date | Jan 30, 2015 |
Publicly Available Date | Apr 5, 2016 |
Journal | Academic Radiology |
Print ISSN | 1076-6332 |
Electronic ISSN | 1878-4046 |
Publisher | Elsevier |
Peer Reviewed | Peer Reviewed |
Volume | 21 |
Issue | 4 |
Pages | 538-545 |
DOI | https://doi.org/10.1016/j.acra.2014.01.003 |
Publisher URL | http://dx.doi.org/10.1016/j.acra.2014.01.003 |
Related Public URLs | http://www.journals.elsevier.com/academic-radiology/ |
Additional Information | Funders : Funder not known |
Files
Academic_Radiology_word_version_with_no_figures.pdf
(507 Kb)
PDF
You might also like
The student perspective of a research-informed teaching activity using simulation
(2024)
Presentation / Conference
Downloadable Citations
About USIR
Administrator e-mail: library-research@salford.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search