Abstract
The non-invasive estimation of hip axial rotation is prone to error. Most of this is likely to originate from soft tissue artefact (STA) at the thigh. The purpose of this study was to evaluate the relative performance of four different thigh cluster configurations. Three were novel
configurations whilst one represented the Helen Hayes convention. Twenty able-bodied adults performed two alternative motor tasks involving hip axial rotation: gait and an isolated longitudinal rotation task. Kinematic data were acquired using a three-dimensional motion analysis system (VICON 512, Oxford Metrics, Oxford, England). Indirect criteria were used to evaluate STA. Hip axial rotation kinematic profiles during gait were highly sensitive to thigh cluster configuration. For the longitudinal rotation task, the various thigh clusters were only capable of estimating, at best, up to 60% of the reference amount of movement. The Helen Hayes convention was associated with the greatest degree of STA. Whilst none of the clusters represented an optimal solution, a non-rigid configuration on the distal thigh provided a more
favourable alternative. The main limitation associated with this study was the absence of a true gold standard measure of hip axial rotation.Until future work provides further insight, one must remain cautious when using estimates of hip axial rotation for purposes of research or
clinical interpretation.
Citation
Schache, A., Baker, R., & Lamoreux, L. (2008). Influence of thigh cluster configuration on the estimation of hip axial rotation. Gait & Posture, 27(1), 60-69. https://doi.org/10.1016/j.gaitpost.2007.01.002
Journal Article Type | Article |
---|---|
Publication Date | Jan 1, 2008 |
Deposit Date | May 12, 2011 |
Journal | Gait & Posture |
Print ISSN | 0966-6362 |
Publisher | Elsevier |
Peer Reviewed | Peer Reviewed |
Volume | 27 |
Issue | 1 |
Pages | 60-69 |
DOI | https://doi.org/10.1016/j.gaitpost.2007.01.002 |
Keywords | Hip, axial rotation, soft tissue artefact, gait analysis |
Publisher URL | http://dx.doi.org/10.1016/j.gaitpost.2007.01.002 |
You might also like
Using the spring-mass model for running : force-length curves and foot-strike patterns
(2020)
Journal Article
Muscle force estimation in clinical gait analysis using AnyBody and OpenSim
(2019)
Journal Article
Is there a minimum complexity required for the biomechanical modelling of running?
(2018)
Journal Article
Downloadable Citations
About USIR
Administrator e-mail: library-research@salford.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search