Dr Stephen Pearson S.Pearson@salford.ac.uk
Senior Lecturer
A variable inertial system for measuring the contractile properties of human muscle
Pearson, S; Harridge, SDR; Grieve, DW; Donald, W; Young, A; Woledge, RC
Authors
SDR Harridge
DW Grieve
W Donald
A Young
RC Woledge
Abstract
Purpose: A flywheel system of variable inertia is described for inferring the mechanical properties of human muscle during a single explosive movement.
Methods: The system consists of a lightweight aluminum disk mounted on a shaft onto which a driving cog is mounted. The inertia of the system can be varied from 0.024 to 0.69 kg[middle dot]m2 by attaching semicircular steel plates to the disk. A rotary encoder detects displacement of the wheel with a resolution of 1[degrees]. Digital signals from the encoder are collected using an A/D converter interfaced to a PC. The data are then processed for the calculation of torque, velocity, power, work done, and acceleration. The mechanical properties of the muscles employed are inferred from calculations of flywheel displacement, time, and force. In addition, a pretension release mechanism can be incorporated into the system to allow isometric force to be developed before movement. This can increase power generation at the low inertias where the time of contraction is typically less than 200 ms. Seven subjects were test-retested using the device. Measures of both average and peak power were made
Results: When mounted in the apparatus described by Bassey and Short, the maximum values for peak and average power were on average 965 +/- 103 and 448 +/- 47 W, respectively. Upon retesting, these results were found to be reliable (cv = 3.3% and 3.0%, respectively).
Conclusions: The inertial system described has been shown to have validity in reproducibility and provided a suitable method of determining a number of muscle output properties during short-term single exertions. This tool could prove useful in a research or clinical setting and may also prove useful as a training device as it negates the need for a strain gauge or goniometer attachment.
Citation
Pearson, S., Harridge, S., Grieve, D., Donald, W., Young, A., & Woledge, R. (2001). A variable inertial system for measuring the contractile properties of human muscle. Medicine and Science in Sports and Exercise, 33(12), 2072-2076. https://doi.org/10.1097/00005768-200112000-00015
Journal Article Type | Article |
---|---|
Acceptance Date | Mar 1, 2001 |
Publication Date | Dec 1, 2001 |
Deposit Date | Aug 9, 2007 |
Journal | Medicine & Science in Sports & Exercise |
Print ISSN | 0195-9131 |
Publisher | Lippincott, Williams & Wilkins |
Peer Reviewed | Peer Reviewed |
Volume | 33 |
Issue | 12 |
Pages | 2072-2076 |
DOI | https://doi.org/10.1097/00005768-200112000-00015 |
Publisher URL | http://dx.doi.org/10.1097/00005768-200112000-00015 |
Related Public URLs | http://journals.lww.com/acsm-msse/pages/default.aspx |
You might also like
Reliability of human achilles tendon stiffness measures using freehand 3-D ultrasound
(2021)
Journal Article
Downloadable Citations
About USIR
Administrator e-mail: library-research@salford.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search