Skip to main content

Research Repository

Advanced Search

The Validity of Hawkin Dynamics Wireless Dual Force Plates for Measuring Countermovement Jump and Drop Jump Variables

J. Badby, Andrew; D. Mundy, Peter; Comfort, Paul; Lake, Jason P.; McMahon, John

The Validity of Hawkin Dynamics Wireless Dual Force Plates for Measuring Countermovement Jump and Drop Jump Variables Thumbnail


Authors

Andrew J. Badby

Peter D. Mundy

Jason P. Lake



Contributors

Valentina Agostini
Editor

Abstract

Force plate testing is becoming more commonplace in sport due to the advent of commercially available, portable, and affordable force plate systems (i.e., hardware and software). Following the validation of the Hawkin Dynamics Inc. (HD) proprietary software in recent literature, the aim of this study was to determine the concurrent validity of the HD wireless dual force plate hardware for assessing vertical jumps. During a single testing session, the HD force plates were placed directly atop two adjacent Advanced Mechanical Technology Inc. in-ground force plates (the “gold standard”) to simultaneously collect vertical ground reaction forces produced by 20 participants (27 ± 6 years, 85 ± 14 kg, 176.5 ± 9.23 cm) during the countermovement jump (CMJ) and drop jump (DJ) tests (1000 Hz). Agreement between force plate systems was determined via ordinary least products regression using bootstrapped 95% confidence intervals. No bias was present between the two force plate systems for any of the CMJ and DJ variables, except DJ peak braking force (proportional bias) and DJ peak braking power (fixed and proportional bias). The HD system may be considered a valid alternative to the industry gold standard for assessing vertical jumps because fixed or proportional bias was identified for none of the CMJ variables (n = 17) and only 2 out of 18 DJ variables.

Citation

J. Badby, A., D. Mundy, P., Comfort, P., Lake, J. P., & McMahon, J. (2023). The Validity of Hawkin Dynamics Wireless Dual Force Plates for Measuring Countermovement Jump and Drop Jump Variables. Sensors, 23(10), 4820. https://doi.org/10.3390/s23104820

Journal Article Type Article
Acceptance Date May 15, 2023
Online Publication Date May 17, 2023
Publication Date 2023-05
Deposit Date Jun 8, 2023
Publicly Available Date Jun 8, 2023
Journal Sensors
Print ISSN 1424-8220
Publisher MDPI
Peer Reviewed Peer Reviewed
Volume 23
Issue 10
Pages 4820
DOI https://doi.org/10.3390/s23104820
Keywords agreement, hardware, accuracy, wireless dual force plate system, force–time, concurrent validity, vertical jump