Why does my prosthetic hand not always do what it is told? (2022)
Journal Article
Chadwell, A., Prince, M., Head, J., Galpin, A., Thies, S., & Kenney, L. (2022). Why does my prosthetic hand not always do what it is told?. Frontiers for Young Minds, 10, https://doi.org/10.3389/frym.2022.786663

There are online videos that appear to show electrically powered prosthetic (artificial) hands to be near-perfect replacements for a missing hand. However, for many users, the reality can be quite different. Prosthetic hands do not always respond as... Read More about Why does my prosthetic hand not always do what it is told?.

The impact of limited prosthetic socket documentation : a researcher perspective (2022)
Journal Article
Olsen, J., Turner, S., Chadwell, A., Dickinson, A., Ostler, C., Armitage, L., …Day, S. (2022). The impact of limited prosthetic socket documentation : a researcher perspective. Frontiers in Rehabilitation Sciences, 3, 853414. https://doi.org/10.3389/fresc.2022.853414

The majority of limb prostheses are socket mounted. For these devices, the socket is essential for adequate prosthetic suspension, comfort, and control. The socket is unique among prosthetic components as it is not usually mass-produced and must inst... Read More about The impact of limited prosthetic socket documentation : a researcher perspective.

Real-world testing of the Self Grasping Hand, a novel adjustable passive prosthesis : a single group pilot study (2022)
Journal Article
O’Brien, L., Montesano, E., Chadwell, A., Kenney, L., & Smit, G. (2022). Real-world testing of the Self Grasping Hand, a novel adjustable passive prosthesis : a single group pilot study. Prosthesis, 4(1), 48-59. https://doi.org/10.3390/prosthesis4010006

(1) Background: This study investigated the feasibility of conducting a two-week “real- world” trial of the Self Grasping Hand (SGH), a novel 3-D printed passive adjustable prosthesis for hand absence; (2) Methods: Single-group pilot study of nine ad... Read More about Real-world testing of the Self Grasping Hand, a novel adjustable passive prosthesis : a single group pilot study.

An evaluation of contralateral hand involvement in the operation of the Delft Self-Grasping Hand, an adjustable passive prosthesis (2021)
Journal Article
Chadwell, A., Chinn, N., Kenney, L., Karthaus, Z., Mos, D., & Smit, G. (2021). An evaluation of contralateral hand involvement in the operation of the Delft Self-Grasping Hand, an adjustable passive prosthesis. PLoS ONE, 16(6), e0252870. https://doi.org/10.1371/journal.pone.0252870

The Delft Self-Grasping Hand is an adjustable passive prosthesis operated using the concept of tenodesis (where opening and closing of the hand is mechanically linked to the flexion and extension of the wrist). As a purely mechanical device that does... Read More about An evaluation of contralateral hand involvement in the operation of the Delft Self-Grasping Hand, an adjustable passive prosthesis.

Addressing unpredictability may be the key to improving performance with current clinically prescribed myoelectric prostheses (2021)
Journal Article
Chadwell, A., Kenney, L., Thies, S., Head, J., Galpin, A., & Baker, R. (2021). Addressing unpredictability may be the key to improving performance with current clinically prescribed myoelectric prostheses. Scientific reports, 11, 3300. https://doi.org/10.1038/s41598-021-82764-6

The efferent control chain for an upper-limb myoelectric prosthesis can be separated into 3 key areas: signal generation, signal acquisition, and device response. Data were collected from twenty trans-radial myoelectric prosthesis users using their o... Read More about Addressing unpredictability may be the key to improving performance with current clinically prescribed myoelectric prostheses.

Evaluating reachable workspace and user control over prehensor aperture for a body-powered prosthesis (2020)
Journal Article
Chadwell, A., Kenney, L., Howard, D., Ssekitoleko, R., Nakandi, B., & Head, J. (2020). Evaluating reachable workspace and user control over prehensor aperture for a body-powered prosthesis. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 28(9), 2005-2014. https://doi.org/10.1109/TNSRE.2020.3010625

Using a shoulder harness and control cable, a person can control the opening and closing of a bodypowered prosthesis prehensor. In many setups the cable does not pass adjacent to the shoulder joint center allowing shoulder flexion on the prostheti... Read More about Evaluating reachable workspace and user control over prehensor aperture for a body-powered prosthesis.

Technology for monitoring everyday prosthesis use : a systematic review (2020)
Journal Article
Chadwell, A., Diment, L., Micó-Amigo, M., Morgado Ramírez, D., Dickinson, A., Granat, M., …Worsley, P. (in press). Technology for monitoring everyday prosthesis use : a systematic review. Journal of NeuroEngineering and Rehabilitation, 17(1), 93. https://doi.org/10.1186/s12984-020-00711-4

Abstract: Background: Understanding how prostheses are used in everyday life is central to the design, provision and evaluation of prosthetic devices and associated services. This paper reviews the scientific literature on methodologies and technolog... Read More about Technology for monitoring everyday prosthesis use : a systematic review.

Upper limb activity of twenty myoelectric prosthesis users and twenty healthy anatomically intact adults (2019)
Journal Article
Chadwell, A., Kenney, L., Granat, M., Thies, S., Galpin, A., & Head, J. (2019). Upper limb activity of twenty myoelectric prosthesis users and twenty healthy anatomically intact adults. Scientific Data, 6(1), 199. https://doi.org/10.1038/s41597-019-0211-6

The upper limb activity of twenty unilateral upper limb myoelectric prosthesis users and twenty anatomically intact adults were recorded over a 7-day period using two wrist worn accelerometers (Actigraph, LLC). This dataset reflects the real-world ac... Read More about Upper limb activity of twenty myoelectric prosthesis users and twenty healthy anatomically intact adults.

Upper- and lower-limb amputees show reduced levels of eeriness for images of prosthetic hands (2019)
Journal Article
Buckingham, G., Parr, J., Wood, G., Day, S., Kenney, L., Galpin, A., …Poliakoff, E. (2019). Upper- and lower-limb amputees show reduced levels of eeriness for images of prosthetic hands. Psychonomic Bulletin and Review, 26, 1295-1302. https://doi.org/10.3758/s13423-019-01612-x

The uncanny phenomenon describes the feeling of unease associated with seeing an image which is close to appearing human. Prosthetic hands in particular are well-known to induce this effect. Little is known, however, about this phenomenon from the vi... Read More about Upper- and lower-limb amputees show reduced levels of eeriness for images of prosthetic hands.

Upper limb activity in myoelectric prosthesis users is biased towards the intact limb and appears unrelated to goal-directed task performance (2018)
Journal Article
Chadwell, A., Kenney, L., Granat, M., Thies, S., Head, J., Galpin, A., & Baker, R. (2018). Upper limb activity in myoelectric prosthesis users is biased towards the intact limb and appears unrelated to goal-directed task performance. Scientific reports, 8, #11084. https://doi.org/10.1038/s41598-018-29503-6

Studies of the effectiveness of prosthetic hands involve assessing user performance on functional tasks in the lab/clinic, sometimes combined with self-report of real-world use. In this paper we compare real-world upper limb activity between a group... Read More about Upper limb activity in myoelectric prosthesis users is biased towards the intact limb and appears unrelated to goal-directed task performance.

Visualisation of upper limb activity using spirals - a new approach to the assessment of daily prosthesis usage (2017)
Journal Article
Chadwell, A., Kenney, L., Granat, M., Thies, S., Head, J., & Galpin, A. (2018). Visualisation of upper limb activity using spirals - a new approach to the assessment of daily prosthesis usage. Prosthetics and Orthotics International, 42(1), 37-44. https://doi.org/10.1177/0309364617706751

BACKGROUND: Current outcome measures used in upper limb myoelectric prosthesis studies include clinical tests of function and self-report questionnaires on real world prosthesis use. Research in other cohorts has questioned both the validity of self-... Read More about Visualisation of upper limb activity using spirals - a new approach to the assessment of daily prosthesis usage.

The reality of myoelectric prostheses : understanding what makes these devices difficult for some users to control (2016)
Journal Article
control. Frontiers in Neurorobotics, 10(7), https://doi.org/10.3389/fnbot.2016.00007

Users of myoelectric prostheses can often find them difficult to control. This can lead to passive-use of the device or total rejection, which can have detrimental effects on the contralateral limb due to overuse. Current clinically available prosth... Read More about The reality of myoelectric prostheses : understanding what makes these devices difficult for some users to control.

Why doesn’t a prosthetic hand always do what it’s told?
Journal Article
Chadwell, A., Prince, M., Head, J., Galpin, A., Thies, S., & Kenney, L. (in press). Why doesn’t a prosthetic hand always do what it’s told?. Frontiers for Young Minds,

There are online videos which appear to show electrically-powered prosthetic hands to be nearperfect replacements for a missing hand (e.g. https://youtu.be/F_brnKz_2tI). However, for many users, the reality can be different. Prosthetic hands don’t a... Read More about Why doesn’t a prosthetic hand always do what it’s told?.