Skip to main content

Research Repository

Advanced Search

All Outputs (47)

An exploration of factors involved in the roll out of a digital application in breast services: A case study approach. (2024)
Journal Article
Mercer, C., Hargreaves, S., Hill, C., Szczepura, K., & Turnbull, R. (2024). An exploration of factors involved in the roll out of a digital application in breast services: A case study approach. Radiography, 30(2), 666-672. https://doi.org/10.1016/j.radi.2024.02.002

Acceptance of new technologies in health care, by those who use them as part of their role, is challenging with confounding contextual factors surrounding the acceptance of technology. As healthcare is rapidly digitising, stakeholder groups should be... Read More about An exploration of factors involved in the roll out of a digital application in breast services: A case study approach..

Understanding experiences of the radiography workforce delivering medical imaging as part of patients' end of life care: An exploratory qualitative interview study. (2023)
Journal Article
Spacey, A., Heaslip, V., & Szczepura, K. (2024). Understanding experiences of the radiography workforce delivering medical imaging as part of patients' end of life care: An exploratory qualitative interview study. Radiography, 30(1), 132-140. https://doi.org/10.1016/j.radi.2023.10.019

People nearing the end of life often require medical imaging in hospitals to manage symptoms and care, despite this little is known about the experiences of those delivering it. The aim of this study is therefore to explore the experiences of the rad... Read More about Understanding experiences of the radiography workforce delivering medical imaging as part of patients' end of life care: An exploratory qualitative interview study..

Skin tears in mammography: A narrative review (2023)
Journal Article
Khan, A., Pradeep, S., Wynn, M., Szczepura, K., Mercer, C., & Stephens, M. (2023). Skin tears in mammography: A narrative review. Journal of Tissue Viability, 32(4), 577-584. https://doi.org/10.1016/j.jtv.2023.09.003

Skin tears are classed as traumatic wounds mainly caused by shearing and frictional forces. Incidences of skin tears are noted to be significant mostly in the elderly population and those with fragile and vulnerable skin. Individuals undergoing mammo... Read More about Skin tears in mammography: A narrative review.

Assessing the impact of binaural and non-binaural auditory beat intervention to pain and compression in mammography (2022)
Journal Article
Nelson, D., Berry, R., Szczepura, K., & Mercer, C. (2022). Assessing the impact of binaural and non-binaural auditory beat intervention to pain and compression in mammography. Radiography, 29(1), 101-108. https://doi.org/10.1016/j.radi.2022.09.005

Pain and discomfort has a negative impact on a patient's overall experience and may impact on subsequent re-attendance to mammography. Pain during mammography remains a significant issue. Assessment of interventions to reduce levels of pain associate... Read More about Assessing the impact of binaural and non-binaural auditory beat intervention to pain and compression in mammography.

The diagnostic value and accuracy of ultrasound in diagnosing hydatidiform mole: A systematic review and meta-analysis of the literature. (2022)
Journal Article
Newhouse, I., Spacey, A., Scragg, B., & Szczepura, K. (2022). The diagnostic value and accuracy of ultrasound in diagnosing hydatidiform mole: A systematic review and meta-analysis of the literature. Radiography, 28(4), 897-905. https://doi.org/10.1016/j.radi.2022.06.005

Hydatidiform moles are the most common type of gestational trophoblastic disease. Internationally the incidence of hydatidiform moles is 1-2:1000 pregnancies. Early detection of women with hydatidiform moles is preferential, as these women are at a h... Read More about The diagnostic value and accuracy of ultrasound in diagnosing hydatidiform mole: A systematic review and meta-analysis of the literature..

Hounsfield Unit inaccuracy in computed tomography lesion size and density, diagnostic quality vs attenuation correction (2017)
Journal Article
Szczepura, K., Thompson, J., & Manning, D. (2017). Hounsfield Unit inaccuracy in computed tomography lesion size and density, diagnostic quality vs attenuation correction. Proceedings of SPIE, 10136, https://doi.org/10.1117/12.2254275

In computed tomography the Hounsfield Units (HU) are used as an indicator of the tissue type based on the linear attenuation coefficients of the tissue. HU accuracy is essential when this metric is used in any form to support diagnosis. In hybrid ima... Read More about Hounsfield Unit inaccuracy in computed tomography lesion size and density, diagnostic quality vs attenuation correction.

Effects of increased compression with an ultrasound transducer on the conspicuity of breast lesions in a phantom (2017)
Journal Article
Szczepura, K., Faqir, T., & Manning, D. (2017). Effects of increased compression with an ultrasound transducer on the conspicuity of breast lesions in a phantom. Proceedings of SPIE, 10136, https://doi.org/10.1117/12.2254263

Ultrasound imaging of the breast is highly operator dependent. The amount of pressure applied with the transducer has a direct impact on the lesion visibility in breast ultrasound. The conspicuity index is a quantitative measure of lesion visibility,... Read More about Effects of increased compression with an ultrasound transducer on the conspicuity of breast lesions in a phantom.

Impact of tube current modulation on lesion conspicuity index in hi-resolution chest computed tomography (2017)
Journal Article
Szczepura, K., Tomkinson, D., & Manning, D. (2017). Impact of tube current modulation on lesion conspicuity index in hi-resolution chest computed tomography. Proceedings of SPIE, 10136, https://doi.org/10.1117/12.2254256

Tube current modulation is a method employed in the use of CT in an attempt to optimize radiation dose to the patient. The acceptable noise (noise index) can be varied, based on the level of optimization required; higher accepted noise reduces the pa... Read More about Impact of tube current modulation on lesion conspicuity index in hi-resolution chest computed tomography.

A JAFROC study of nodule detection performance in CT images of a thorax acquired during PET/CT (2017)
Journal Article
Thompson, J., Wareing, A., Szczepura, K., Vinjamuri, S., & Hogg, P. (2017). A JAFROC study of nodule detection performance in CT images of a thorax acquired during PET/CT. Radiography, 23(3), 191-196. https://doi.org/10.1016/j.radi.2017.03.001

Purpose Two types of CT images (modalities) are acquired in PET/CT: for attenuation correction (AC) and diagnosis. The purpose of the study was to compare nodule detection and localization performance between these two modalities. Methods CT... Read More about A JAFROC study of nodule detection performance in CT images of a thorax acquired during PET/CT.

Analysis of effective and organ dose estimation in CT when using mA modulation : a single scanner pilot study (2017)
Journal Article
Tootell, A., Szczepura, K., & Hogg, P. (2017). Analysis of effective and organ dose estimation in CT when using mA modulation : a single scanner pilot study. Radiography, 23(2), 159-166. https://doi.org/10.1016/j.radi.2017.02.006

Effective dose (ED) estimation in CT examinations can be obtained by combining dose length product (DLP) with published ED per DLP coefficients or performed using software. These methods do not account for tube current (mA) modulation which is influe... Read More about Analysis of effective and organ dose estimation in CT when using mA modulation : a single scanner pilot study.

Effective dose and effective risk from post-SPECT imaging of the lumbar spine (2016)
Journal Article
Tootell, A., McEntee, M., Szczepura, K., & Hogg, P. (2016). Effective dose and effective risk from post-SPECT imaging of the lumbar spine. Journal of Medical Imaging and Radiation Sciences, 47(3), 267-275. https://doi.org/10.1016/j.jmir.2016.04.012

Purpose Planar bone scans play an important role in the staging and monitoring of malignancy and metastases. Metastases in the lumbar spine are associated with significant morbidity, therefore accurate diagnosis is essential. Supplementary imaging... Read More about Effective dose and effective risk from post-SPECT imaging of the lumbar spine.

Validated novel software to measure the conspicuity index of lesions in DICOM images (2016)
Journal Article
Szczepura, K., & Manning, D. (2016). Validated novel software to measure the conspicuity index of lesions in DICOM images. Proceedings of SPIE, 9787, https://doi.org/10.1117/12.2216211

Description of purpose A novel software programme and associated Excel spreadsheet has been developed to provide an objective measure of the expected visual detectability of focal abnormalities within DICOM images. Methodology ROIs are drawn ar... Read More about Validated novel software to measure the conspicuity index of lesions in DICOM images.

Effect of reconstruction methods and x-ray tube current-time product on nodule detection in an anthropomorphic thorax phantom : a crossed-modality JAFROC observer study (2016)
Journal Article
Thompson, J., Chakraborty, D., Szczepura, K., Tootell, A., Vamvakas, I., Manning, D., & Hogg, P. (2016). Effect of reconstruction methods and x-ray tube current-time product on nodule detection in an anthropomorphic thorax phantom : a crossed-modality JAFROC observer study. Medical Physics, 43(3), 1265-1274. https://doi.org/10.1118/1.4941017

Purpose: To evaluate nodule detection in an anthropomorphic chest phantom in computed tomography (CT) images reconstructed with adaptive iterative dose reduction 3D (AIDR3D) and filtered back projection (FBP) over a range of tube current-time product... Read More about Effect of reconstruction methods and x-ray tube current-time product on nodule detection in an anthropomorphic thorax phantom : a crossed-modality JAFROC observer study.

Does elevating image receptor increase breast receptor footprint and improve pressure balance? (2015)
Journal Article
Smith, H., Szczepura, K., Mercer, C., Maxwell, A., & Hogg, P. (2015). Does elevating image receptor increase breast receptor footprint and improve pressure balance?. Radiography, 21(4), 359-363. https://doi.org/10.1016/j.radi.2015.02.001

There is no consensus in the literature regarding the image receptor (IR) position for the cradio-caudal projection in mammography. Some literature indicates the IR should be positioned to the infra mammary fold (IMF); other literature suggests the... Read More about Does elevating image receptor increase breast receptor footprint and improve pressure balance?.

A phantom-based JAFROC observer study of two CT reconstruction methods : the search for optimisation of lesion detection and effective dose (2015)
Journal Article
Mello-Thoms, C., Kupinski, M., Thompson, J., Chakraborty, D., Szczepura, K., Vamvakas, I., …Hogg, P. (2015). A phantom-based JAFROC observer study of two CT reconstruction methods : the search for optimisation of lesion detection and effective dose. Proceedings of SPIE, 9416, 94160B. https://doi.org/10.1117/12.2081632

Purpose: To investigate the dose saving potential of iterative reconstruction (IR) in a computed tomography (CT) examination of the thorax. Materials and Methods: An anthropomorphic chest phantom containing various configurations of simulated lesi... Read More about A phantom-based JAFROC observer study of two CT reconstruction methods : the search for optimisation of lesion detection and effective dose.

Comparison of effective dose and lifetime risk of cancer Incidence of CT attenuation correction acquisitions and radiopharmaceutical administration for myocardial perfusion imaging (2014)
Journal Article
Tootell, A., Szczepura, K., & Hogg, P. (2014). Comparison of effective dose and lifetime risk of cancer Incidence of CT attenuation correction acquisitions and radiopharmaceutical administration for myocardial perfusion imaging. British Journal of Radiology, 87(1041), 20140110. https://doi.org/10.1259/bjr.20140110

Objective: To measure the organ dose and calculate effective dose from CT attenuation correction (CTAC) acquisitions from four commonly used gamma camera single photon emission CT/CT systems. Methods: CTAC dosimetry data was collected using therm... Read More about Comparison of effective dose and lifetime risk of cancer Incidence of CT attenuation correction acquisitions and radiopharmaceutical administration for myocardial perfusion imaging.

A 6 year study of mammographic compression force : practitioner variability within and between screening sites (2014)
Journal Article
Mercer, C., Szczepura, K., Kelly, J., Millington, S., Denton, D., Borgen, R., …Hogg, P. (2015). A 6 year study of mammographic compression force : practitioner variability within and between screening sites. Radiography, 21(1), 68-73. https://doi.org/10.1016/j.radi.2014.07.004

Background The application of compression force in mammography is more heavily influenced by the practitioner rather than the client. This can affect client experience, radiation dose and image quality. This research investigates practitioner comp... Read More about A 6 year study of mammographic compression force : practitioner variability within and between screening sites.

An overview of measuring and modelling dose and risk from ionising radiation for medical exposures (2014)
Journal Article
risk from ionising radiation for medical exposures. Radiography, 20(4), 323-332. https://doi.org/10.1016/j.radi.2014.05.002

PURPOSE: This paper gives an overview of the methods that are used to calculate dose and risk from exposure to ionizing radiation as a support to other papers in this special issue. BACKGROUND: The optimization of radiation dose is a legal requir... Read More about An overview of measuring and modelling dose and risk from ionising radiation for medical exposures.

An audit to investigate the impact of false positive breast screening results and diagnostic work-up on re-engagement with subsequent routine screening (2014)
Journal Article
Nightingale, J., Borgen, R., Porter-Bennett, L., & Szczepura, K. (2014). An audit to investigate the impact of false positive breast screening results and diagnostic work-up on re-engagement with subsequent routine screening. Radiography, 21(1), 7-10. https://doi.org/10.1016/j.radi.2014.05.005

Introduction: Women attending breast screening may have suspicious mammographic findings that are subsequently found at assessment clinic to be normal (false positive, FP). A false positive diagnosis is not harmless, with short and long term negativ... Read More about An audit to investigate the impact of false positive breast screening results and diagnostic work-up on re-engagement with subsequent routine screening.

Breast tissue bulge and lesion visibility during stereotactic biopsy – a phantom study (2014)
Journal Article
Williams, S., Hackney, L., Hogg, P., & Szczepura, K. (2014). Breast tissue bulge and lesion visibility during stereotactic biopsy – a phantom study. Radiography, 20(3), 271-276. https://doi.org/10.1016/j.radi.2014.04.006

Background During mammography guided stereotactic breast biopsy a bulge of tissue can form in the paddle needle biopsy aperture. This bulge has been estimated to have a height of up to 30% of the breast itself. During clinical biopsy we have noti... Read More about Breast tissue bulge and lesion visibility during stereotactic biopsy – a phantom study.