Accuracy of the Polar FT40M heart rate monitor in estimating energy expenditure during treadmill running
Marsh, CE; Pender, D
Authors
D Pender
Abstract
Estimation of energy expenditure (EE) from heart rate (HR) monitors has been reported to provide inaccurate predictions of EE during exercise by some studies, whilst others have reported good predictive accuracy. Some of the discrepancies reported could be related to the exercise intensity used where accuracy could be influenced by the upper/lower HR ranges utilised, and whether male or female participants were used as gender has been reported to influence predictive accuracy. Therefore, the purpose of this study was to examine the accuracy of the Polar FT40M heart rate monitor (HRM) in estimating EE during treadmill running at four exercise intensities in males and females. Following institutional ethics approval, six male (mean ± SD: age = 24.33 ± 3.82 years, height = 180.67 ± 7.54 cm, weight = 81.67 ± 13.16 kg) and six female (mean ± SD: age = 22.17± 3.13 years, height = 162.67 ± 4.82 cm, weight = 59 ± 3.16 kg) participants conducted a preliminary trial to determine treadmill running speeds which correspond to 55%, 65%, 75% and 85% of estimated HRmax. The participants then performed four steady-state submaximal trials at the speeds determined during the preliminary trials. EE was measured using indirect calorimetry (IC) (Cortex Metalyzer 3b) and estimated using HRM simultaneously for 5 min at each intensity. A three-way ANOVA (measuring device [IC/HRM] × intensity × gender) was conducted to compare the mean EE. There was no significant difference (P = 403) in average gross EE (all intensities) between IC (45.3 ± 2.9 kcal) compared to HRM (44.1 ± 2.0 kcal). Measured and predicted EE differed most (16.4%) at 55% HRmax and least (1.4%) at 75% HRmax, but intensity did not have a significant effect (P = 0.068) on the accuracy of HRM estimation of EE (IC: 29.7 ± 15.7, 41.2 ± 16.5, 50.9 ± 15.4, 59.5 ± 14.4 vs. PHRM: 24.8 ± 5.4, 38.3 ± 8.0, 51.7 ± 9.3 and 61.6 ± 10.2 kcal for 55%, 65%, 75% and 85% HRmax, respectively). There was also no significant gender effect at each intensity (P = 0.178), but when comparing average gross EE, gender significantly affected the accuracy of the HRM (P = 0.012) with an overestimation of EE in females (IC: 34.2 ± 13.1 vs. HRM: 40.6 ± 15.2 kcal, P < 0.01, effect size = 0.45) and underestimation in males (IC: 56.5 ± 12.7 vs. HRM: 47.6 ± 16.9 kcal, P < 0.01, effect size = −0.59). The results show that the Polar FT40M HRM provides good predictive accuracy of EE across different exercise intensities, but gross average EE is influenced by gender with an overestimation of EE in females and underestimation in males.
Citation
Marsh, C., & Pender, D. Accuracy of the Polar FT40M heart rate monitor in estimating energy expenditure during treadmill running. Poster presented at British Association of Sport and Exercise Sciences (BASES) Conference 2015, St. George's Park, Burton upon Trent, Staffordshire, United Kingdom
Presentation Conference Type | Poster |
---|---|
Conference Name | British Association of Sport and Exercise Sciences (BASES) Conference 2015 |
Conference Location | St. George's Park, Burton upon Trent, Staffordshire, United Kingdom |
End Date | Dec 2, 2015 |
Online Publication Date | Nov 25, 2015 |
Publication Date | Dec 2, 2015 |
Deposit Date | Nov 27, 2020 |
Publisher URL | https://doi.org/10.1080/02640414.2015.1115651 |
Related Public URLs | https://www.tandfonline.com/toc/rjsp20/current |
Additional Information | Access Information : This published poster presentation abstract can be read using the link above. Event Type : Conference |
You might also like
The role of hypocapnia in the development of syncope during orthostatic stress following plasma volume expansion
(-0001)
Presentation / Conference
The effects of external nasal dilator strips on gas exchange and ventilation during exercise
(-0001)
Presentation / Conference
Comparison of blood lactate concentration
between the Biosen C-Line and the Analox GM7
lactate analysers during incremental exercise
(-0001)
Presentation / Conference
Does a high-intensity warm-up benefit 5-km running performance?
(-0001)
Presentation / Conference
Downloadable Citations
About USIR
Administrator e-mail: library-research@salford.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search