Clare Marsh C.Marsh@salford.ac.uk
Senior Lecturer
The purpose of this study was to assess the validity of the American College of Sports Medicine's (ACSM's) submaximal treadmill running test in predicting V̇o2max. Twenty-one moderately well-trained men aged 18–34 years performed 1 maximal treadmill test to determine maximal oxygen uptake (M V̇o2max) and 2 submaximal treadmill tests using 4 stages of continuous submaximal exercise. Estimated V̇o2max was predicted by extrapolation to age-predicted maximal heart rate (HRmax) and calculated in 2 ways: using data from all submaximal stages between 110 b·min−1 and 85% HRmax (P V̇o2max-All), and using data from the last 2 stages only (P V̇o2max-2). The measured V̇o2max was overestimated by 3% on average for the group but was not significantly different to predicted V̇o2max (1-way analysis of variance [ANOVA] p = 0.695; M V̇o2max = 53.01 ± 5.38; P V̇o2max-All = 54.27 ± 7.16; P V̇o2max-2 = 54.99 ± 7.69 ml·kg−1·min−1), although M V̇o2max was not overestimated in all the participants—it was underestimated in 30% of observations. Pearson's correlation, standard error of estimate (SEE), and total error (E) between measured and predicted V̇o2max were r = 0.646, 4.35, 4.08 ml·kg−1·min−1 (P V̇o2max-All) and r = 0.642, 4.21, 3.98 ml·kg−1·min−1 (P V̇o2max-2) indicating that the accuracy in prediction (error) was very similar whether using P V̇o2max-All or P V̇o2max-2, with up to 70% of the participants predicted scores within 1 SEE (∼4 ml·kg−1·min−1) of M V̇o2max. In conclusion, the ACSM equation provides a reasonably good estimation of V̇o2max with no difference in predictive accuracy between P V̇o2max-2 and P V̇o2max-All, and hence, either approach may be equally useful in tracking an individual's aerobic fitness over time. However, if a precise knowledge of V̇o2max is required, then it is recommended that this be measured directly.
Journal Article Type | Article |
---|---|
Publication Date | 2012-02 |
Deposit Date | Jul 3, 2015 |
Journal | Journal of Strength and Conditioning Research |
Print ISSN | 1064-8011 |
Electronic ISSN | 1533-4287 |
Publisher | Lippincott, Williams & Wilkins |
Peer Reviewed | Peer Reviewed |
Volume | 26 |
Issue | 2 |
Pages | 548-554 |
DOI | https://doi.org/10.1519/JSC.0b013e3181bac56e |
Publisher URL | http://dx.doi.org/10.1519/JSC.0b013e3181bac56e |
Related Public URLs | http://journals.lww.com/nsca-jscr/pages/default.aspx |
Comparison of blood lactate concentration
between the Biosen C-Line and the Analox GM7
lactate analysers during incremental exercise
(2016)
Presentation / Conference Contribution
Accuracy of the Polar FT40M heart rate monitor in estimating energy expenditure during treadmill running
(2015)
Presentation / Conference Contribution
Does a high-intensity warm-up benefit 5-km running performance?
(2014)
Presentation / Conference Contribution
The effect of mouthguard use on ventilatory response to submaximal exercise
(2014)
Presentation / Conference Contribution
About USIR
Administrator e-mail: library-research@salford.ac.uk
This application uses the following open-source libraries:
Apache License Version 2.0 (http://www.apache.org/licenses/)
Apache License Version 2.0 (http://www.apache.org/licenses/)
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search