BACKGROUND: When determining achievement of maximal oxygen uptake (VO2max) during treadmill running using speed increments, the VO2 cut-off criteria applied during plateau identification is often not justified, not protocol specific, or not related to actual change in VO2 (ΔVO2) with speed increment, which can influence plateau achievement rates between studies. The purpose of this study was to compare plateau incidence using an individualised plateau criteria approach based on a ‘percentage’ ΔVO2 compared to using previously established criteria of ΔVO2≤2.1 ml-kg-1⋅min-1 not developed on running speed.
METHODS: Fifty-four males completed a ramp horizontal treadmill test with 0.5 or 1.0 km⋅h-1 per minute (km⋅h-1⋅min-1) speed increments to measure VO2max. Average ΔVO2 for the each 1-minute speed increment was determined and used to develop individualised cut-off criteria deemed to be a plateau: a final ΔVO2 of less than 50% of the average change elicited between consecutive speed increments during the test ( VO2≤50%); plateau incidence using this was compared to ΔVO2 ≤2.1 ml⋅kg-1⋅min-1 ( VO2≤2.1).
RESULTS: Mean ΔVO2 was 1.74±0.59 and 3.09±0.59 ml⋅kg-1⋅ min-1 for 0.5 and 1.0 km⋅ h-1⋅ min-1 increments respectively. VO2 cut-off criteria were met by 48%/65% (1.0 km⋅h-1⋅min-1) (P=0.234) and 53%/100% (0.5 km⋅h-1⋅ min-1) (P=0.003) for VO2≤50% and VO2≤2.1 respectively.
CONCLUSIONS: Use of VO2≤2.1 resulted in distortedly high plateau achievement, particularly for smaller speed increments where the VO2-speed relationship was actually less than VO2≤2.1 making its use inappropriate. Use of VO2≤50% may be a suitable alternative, but as a plateau was not consistently demonstrated, application of cut-off criteria should not be a requirement in deciding whether one’s achieved VO2max.
KEYWORDS: VO2-speed relationship - VO2 plateau - VO2 cut-off criteria - Horizontal treadmill running
Journal Article Type | Article |
---|---|
Online Publication Date | Jan 4, 2018 |
Publication Date | Jan 4, 2018 |
Deposit Date | Feb 26, 2018 |
Publicly Available Date | Jan 4, 2019 |
Journal | Journal of Sports Medicine and Physical Fitness |
Print ISSN | 0022-4707 |
Electronic ISSN | 1827-1928 |
Publisher | Edizioni Minerva Medica |
Volume | 59 |
Issue | 1 |
Pages | 10-16 |
DOI | https://doi.org/10.23736/S0022-4707.18.07952-5 |
Publisher URL | http://dx.doi.org/10.23736/S0022-4707.18.07952-5 |
Related Public URLs | https://www.minervamedica.it/en/journals/sports-med-physical-fitness/issue.php?cod=R40Y2018N03 |
Manuscript - Validity of VO2 cut-off criteria - USIR.pdf
(295 Kb)
PDF
Comparison of blood lactate concentration
between the Biosen C-Line and the Analox GM7
lactate analysers during incremental exercise
(2016)
Presentation / Conference Contribution
Accuracy of the Polar FT40M heart rate monitor in estimating energy expenditure during treadmill running
(2015)
Presentation / Conference Contribution
Does a high-intensity warm-up benefit 5-km running performance?
(2014)
Presentation / Conference Contribution
The effect of mouthguard use on ventilatory response to submaximal exercise
(2014)
Presentation / Conference Contribution
About USIR
Administrator e-mail: library-research@salford.ac.uk
This application uses the following open-source libraries:
Apache License Version 2.0 (http://www.apache.org/licenses/)
Apache License Version 2.0 (http://www.apache.org/licenses/)
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search