Skip to main content

Research Repository

Advanced Search

Outputs (118)

Upper limb activity in myoelectric prosthesis users is biased towards the intact limb and appears unrelated to goal-directed task performance (2018)
Journal Article
Chadwell, A., Kenney, L., Granat, M., Thies, S., Head, J., Galpin, A., & Baker, R. (2018). Upper limb activity in myoelectric prosthesis users is biased towards the intact limb and appears unrelated to goal-directed task performance. Scientific reports, 8, #11084. https://doi.org/10.1038/s41598-018-29503-6

Studies of the effectiveness of prosthetic hands involve assessing user performance on functional tasks in the lab/clinic, sometimes combined with self-report of real-world use. In this paper we compare real-world upper limb activity between a group... Read More about Upper limb activity in myoelectric prosthesis users is biased towards the intact limb and appears unrelated to goal-directed task performance.

FES-UPP : a flexible functional electrical stimulation system to support upper limb functional activity practice (2018)
Journal Article
Sun, M., Smith, C., Howard, D., Kenney, L., Luckie, H., Waring, K., …Finn, S. (2018). FES-UPP : a flexible functional electrical stimulation system to support upper limb functional activity practice. Frontiers in Neuroscience, 12(449), https://doi.org/10.3389/fnins.2018.00449

There is good evidence supporting highly intensive, repetitive, activity-focused, voluntary-initiated practice as a key to driving recovery of upper limb function following stroke. Functional electrical stimulation (FES) offers a potential mechanism... Read More about FES-UPP : a flexible functional electrical stimulation system to support upper limb functional activity practice.

Methods for the real-world evaluation of fall detection technology : a scoping review (2018)
Journal Article
Broadley, R., Klenk, J., Thies, S., Kenney, L., & Granat, M. (2018). Methods for the real-world evaluation of fall detection technology : a scoping review. Sensors, 18(7), https://doi.org/10.3390/s18072060

Falls in older adults present a major growing healthcare challenge and reliable detection of falls is crucial to minimise their consequences. The majority of development and testing has used laboratory simulations. As simulations do not cover the w... Read More about Methods for the real-world evaluation of fall detection technology : a scoping review.

Performance of optimised prosthetic ankle designs that are based on a hydraulic variable displacement actuator (VDA) (2017)
Journal Article
Gardiner, J., Bari, A., Kenney, L., Twiste, M., Moser, D., Zahedi, S., & Howard, D. (2017). Performance of optimised prosthetic ankle designs that are based on a hydraulic variable displacement actuator (VDA). IEEE Transactions on Neural Systems and Rehabilitation Engineering, 25(12), 2418-2426. https://doi.org/10.1109/TNSRE.2017.2763999

Current energy storage and return (ESR) prosthetic feet only marginally reduce the cost of amputee locomotion compared to basic solid ankle cushioned heel (SACH) feet, possibly due to their lack of push-off at the end of stance. To our knowledge,... Read More about Performance of optimised prosthetic ankle designs that are based on a hydraulic variable displacement actuator (VDA).

Functional electrical stimulation and ankle foot orthoses provide equivalent therapeutic effects on foot drop : a meta-analysis providing direction for future research (2017)
Journal Article
Prenton, S., Hollands, K., Kenney, L., & Onmanee, P. (2017). Functional electrical stimulation and ankle foot orthoses provide equivalent therapeutic effects on foot drop : a meta-analysis providing direction for future research. Journal of Rehabilitation Medicine, 50(2), https://doi.org/10.2340/16501977-2289

Objective: To compare the randomized controlled trial evidence for therapeutic effects on walking of functional electrical stimulation and ankle foot orthoses for foot drop caused by central nervous system conditions. Data sources: MEDLINE,... Read More about Functional electrical stimulation and ankle foot orthoses provide equivalent therapeutic effects on foot drop : a meta-analysis providing direction for future research.

A generalizable methodology for stability assessment of walking aid users (2017)
Journal Article
Costamagna, E., Thies, S., Kenney, L., Howard, D., Liu, A., & Ogden, D. (2017). A generalizable methodology for stability assessment of walking aid users. Medical Engineering and Physics, 47, 167-175. https://doi.org/10.1016/j.medengphy.2017.06.013

To assist balance and mobility, older adults are often prescribed walking aids. Nevertheless, surprisingly their use has been associated with increased falls-risk. To address this finding we first need to characterise a person’s stability while using... Read More about A generalizable methodology for stability assessment of walking aid users.

Skill assessment in upper limb myoelectric prosthesis users : validation of a clinically feasible method for characterising upper limb temporal and amplitude variability during the performance of functional tasks (2017)
Journal Article
Thies, S., Kenney, L., Sobuh, M., Galpin, A., Kyberd, P., Stine, R., & Major, M. (2017). Skill assessment in upper limb myoelectric prosthesis users : validation of a clinically feasible method for characterising upper limb temporal and amplitude variability during the performance of functional tasks. Medical Engineering and Physics, 47, 137-143. https://doi.org/10.1016/j.medengphy.2017.03.010

Upper limb myoelectric prostheses remain challenging to use and are often abandoned. A proficient user must be able to plan/execute arm movements while activating the residual muscle(s), accounting for delays and unpredictability in prosthesis respon... Read More about Skill assessment in upper limb myoelectric prosthesis users : validation of a clinically feasible method for characterising upper limb temporal and amplitude variability during the performance of functional tasks.

Visualisation of upper limb activity using spirals - a new approach to the assessment of daily prosthesis usage (2017)
Journal Article
Chadwell, A., Kenney, L., Granat, M., Thies, S., Head, J., & Galpin, A. (2018). Visualisation of upper limb activity using spirals - a new approach to the assessment of daily prosthesis usage. Prosthetics and Orthotics International, 42(1), 37-44. https://doi.org/10.1177/0309364617706751

BACKGROUND: Current outcome measures used in upper limb myoelectric prosthesis studies include clinical tests of function and self-report questionnaires on real world prosthesis use. Research in other cohorts has questioned both the validity of self-... Read More about Visualisation of upper limb activity using spirals - a new approach to the assessment of daily prosthesis usage.

Characterisation of rollator use using inertial sensors (2016)
Journal Article
Cheng, T., Kenney, L., Amor, J., Thies, S., Costamagna, E., James, C., & Holloway, C. (2016). Characterisation of rollator use using inertial sensors. Healthcare Technology Letters, 3(4), https://doi.org/10.1049/htl.2016.0061

The use of walking aids is prevalent among older people and people with mobility impairment. Rollators are designed to support outdoor mobility and require the user to negotiate curbs and slopes in the urban environment. Despite the prevalence of rol... Read More about Characterisation of rollator use using inertial sensors.

Crowd-sourced amputee gait data : a feasibility study using YouTube videos of unilateral trans-femoral gait (2016)
Journal Article
Gardiner, J., Gunarathne, N., Howard, D., & Kenney, L. (2016). Crowd-sourced amputee gait data : a feasibility study using YouTube videos of unilateral trans-femoral gait. PLoS ONE, 11(10), e0165287. https://doi.org/10.1371/journal.pone.0165287

Collecting large datasets of amputee gait data is notoriously difficult. Additionally, collecting data on less prevalent amputations or on gait activities other than level walking and running on hard surfaces is rarely attempted. However, with the we... Read More about Crowd-sourced amputee gait data : a feasibility study using YouTube videos of unilateral trans-femoral gait.