A 6 year study of mammographic compression force : practitioner variability within and between screening sites (2014)
Journal Article

Background
The application of compression force in mammography is more heavily influenced by the practitioner rather than the client. This can affect client experience, radiation
dose and image quality. This research investigates practitioner comp... Read More about A 6 year study of mammographic compression force : practitioner variability within and between screening sites.

An audit to investigate the impact of false positive breast screening results and diagnostic work-up on re-engagement with subsequent routine screening (2014)
Journal Article
Nightingale, J., Borgen, R., Porter-Bennett, L., & Szczepura, K. (2014). An audit to investigate the impact of false positive breast screening results and diagnostic work-up on re-engagement with subsequent routine screening. Radiography, 21(1), 7-10. https://doi.org/10.1016/j.radi.2014.05.005

Introduction: Women attending breast screening may have suspicious mammographic findings that are subsequently found at assessment clinic to be normal (false positive, FP). A false positive diagnosis is not harmless, with short and long term negativ... Read More about An audit to investigate the impact of false positive breast screening results and diagnostic work-up on re-engagement with subsequent routine screening.

Breast tissue bulge and lesion visibility during stereotactic biopsy – a phantom study (2014)
Journal Article
Williams, S., Hackney, L., Hogg, P., & Szczepura, K. (2014). Breast tissue bulge and lesion visibility during stereotactic biopsy – a phantom study. Radiography, 20(3), 271-276. https://doi.org/10.1016/j.radi.2014.04.006

Background

During mammography guided stereotactic breast biopsy a bulge of tissue can form in the paddle needle biopsy aperture. This bulge has been estimated to have a height of up to 30% of the breast itself. During clinical biopsy we have noti... Read More about Breast tissue bulge and lesion visibility during stereotactic biopsy – a phantom study.

A free-response evaluation determining value in the computed tomography attenuation correction image for revealing pulmonary incidental findings : a phantom study (2014)
Journal Article
Thompson, J., Hogg, P., Manning, D., Szczepura, K., & Chakraborty, D. (2014). A free-response evaluation determining value in the computed tomography attenuation correction image for revealing pulmonary incidental findings : a phantom study. Academic radiology, 21(4), 538-545. https://doi.org/10.1016/j.acra.2014.01.003

RATIONALE AND OBJECTIVES: The purpose of this study was to compare lesion-detection performance when interpreting computed tomography (CT) images that are acquired for attenuation correction when performing single photon emission computed tomography/... Read More about A free-response evaluation determining value in the computed tomography attenuation correction image for revealing pulmonary incidental findings : a phantom study.

Fact or fiction : an analysis of the 10 kVp ‘rule’ in computed radiography (2013)
Journal Article
radiography. Radiography, 19(3), 223-227. https://doi.org/10.1016/j.radi.2013.05.003

Purpose: To determine whether increasing the tube voltage by 10 kVp whilst reducing the tube current by
50% (10 kVp ‘rule’) produces similar perceptual image quality.
Method: 391 matched pairs of anthropomorphic chest phantom X-ray images were pro... Read More about Fact or fiction : an analysis of the 10 kVp ‘rule’ in computed radiography.

Tissue bulge during stereotactic core biopsy (2013)
Journal Article
Hackney, L., Williams, S., Hogg, P., & Szczepura, K. (2013). Tissue bulge during stereotactic core biopsy. Radiography, 19(4), 366-368. https://doi.org/10.1016/j.radi.2013.06.007

In full field digital mammography (FFDM) the whole breast is subjected to compression with a perspex compression paddle in order to reduce breast thickness and improve image quality. Once a mammographic abnormality has been detected using FFDM and a... Read More about Tissue bulge during stereotactic core biopsy.

A method to measure paddle and detector pressures and footprints in mammography (2013)
Journal Article
Hogg, P., Szczepura, K., Darlington, A., & Maxwell, A. (2013). A method to measure paddle and detector pressures and footprints in mammography. Medical Physics, 40(4), 041907. https://doi.org/10.1118/1.4792720

Purpose:
Compression is necessary in mammography to improve image quality and reduce radiation burden. Maximizing the amount of breast in contact with the image receptor (IR) is important. To achieve this, for the craniocaudal projection, there is n... Read More about A method to measure paddle and detector pressures and footprints in mammography.

Optimising the number of thermoluminescent dosimeters required for the measurement of effective dose for computed tomography attenuation correction data in SPECT/CT myocardial perfusion imaging (2013)
Journal Article
Tootell, A., Szczepura, K., & Hogg, P. (2013). Optimising the number of thermoluminescent dosimeters required for the measurement of effective dose for computed tomography attenuation correction data in SPECT/CT myocardial perfusion imaging. Radiography, 19(1), 42-47. https://doi.org/10.1016/j.radi.2012.11.001

Background

The use of thermoluminescent dosimeters (TLDs) is regarded as time consuming and laborious. As part of our dosimetry research it was necessary to optimise the use of our resources, both physical and time. Experimental work was carried... Read More about Optimising the number of thermoluminescent dosimeters required for the measurement of effective dose for computed tomography attenuation correction data in SPECT/CT myocardial perfusion imaging.

Pressure and breast thickness in mammography : an exploratory calibration study (2013)
Journal Article
Hogg, P., Taylor, M., Szczepura, K., Mercer, C., & Denton, E. (2013). Pressure and breast thickness in mammography : an exploratory calibration study. British Journal of Radiology, 86(1021), 1-7. https://doi.org/10.1259/bjr.20120222

Objective To perform a calibration study to provide data to help improve consistency in the pressure that is applied during mammography.

Methods Automatic readouts of breast thickness accuracy vary between mammography machines; therefore, one m... Read More about Pressure and breast thickness in mammography : an exploratory calibration study.

Analysis of CT acquisition parameters suitable for use in SPECT/CT : a free-response receiver operating characteristic study (2012)
Journal Article
Thompson, J., Hogg, P., Szczepura, K., & Manning, D. (2012). Analysis of CT acquisition parameters suitable for use in SPECT/CT : a free-response receiver operating characteristic study. Radiography, 18(4), 238-243. https://doi.org/10.1016/j.radi.2012.05.004

Purpose

This dose optimisation free-response receiver operating characteristic (FROC) study compares the diagnostic performance of 8 CT acquisition parameter settings suitable for use with diagnostic quality SPECT/CT systems. Observers were requi... Read More about Analysis of CT acquisition parameters suitable for use in SPECT/CT : a free-response receiver operating characteristic study.

ROCView : prototype software for data collection in jackknife alternative free-response receiver operating characteristic analysis (2012)
Journal Article

ROCView has been developed as an image display and response capture (IDRC) solution to image display and consistent recording of reader responses in relation to the free-response receiver operating characteristic paradigm. A web-based solution to IDR... Read More about ROCView : prototype software for data collection in jackknife alternative free-response receiver operating characteristic analysis.

The readout thickness versus the measured thickness for a range of screen film mammography (SFM) and full-field digital mammography (FFDM) units (2011)
Journal Article
Hauge, I., Hogg, P., Szczepura, K., Connolly, P., McGill, G., & Mercer, C. (2011). The readout thickness versus the measured thickness for a range of screen film mammography (SFM) and full-field digital mammography (FFDM) units. Medical Physics, 39(1), 263-271. https://doi.org/10.1118/1.3663579

PURPOSE: To establish a simple method to determine breast readout accuracy on mammography units. METHODS: A thickness measuring device (TMD) was used in conjunction with a breast phantom. This phantom had compression characteristics similar to human... Read More about The readout thickness versus the measured thickness for a range of screen film mammography (SFM) and full-field digital mammography (FFDM) units.

Quantification of neutrophil migration into the lungs of patients with chronic obstructive pulmonary disease (2011)
Journal Article

Objective: to quantify neutrophil migration into the lungs of patients with chronic pulmonary obstructive disease (COPD).
Methods: neutrophil loss via airways was assessed by dedicated whole-body counting 45 min, 24 h and 2, 4, 7 and 10 days after... Read More about Quantification of neutrophil migration into the lungs of patients with chronic obstructive pulmonary disease.

Measuring whole-body neutrophil redistribution using a dedicated whole-body counter and ultra-low doses of 111 Indium (2011)
Journal Article

Background - There is increasing interest in the ‘homing’ of neutrophils to bone marrow. The aim of this study was to measure the whole-body redistribution of 111In using a whole-body counter following the administration of ultra-small activities of... Read More about Measuring whole-body neutrophil redistribution using a dedicated whole-body counter and ultra-low doses of 111 Indium.

Does P-glycoprotein have a role in the lung clearances of inhaled 99m Tc-sestamibi and 99m Tc-tetrofosmin? (2009)
Journal Article

Objective - The clearance rate of inhaled 99mTc-sestamibi
from the lungs of healthy nonsmoking individuals is much slower than would be expected from its physical properties. The clearance rate is even slower in healthy cigarette smokers. As 99mTc-s... Read More about Does P-glycoprotein have a role in the lung clearances of inhaled 99m Tc-sestamibi and 99m Tc-tetrofosmin?.

Does P-glycoprotein have a role in the lung clearances of inhaled 99mTc-sestamibi and 99mTc-tetrofosmin? (2009)
Journal Article

Objective
The clearance rate of inhaled 99mTc-sestamibi from the lungs of healthy nonsmoking individuals is much slower than would be expected from its physical properties. The clearance rate is even slower in healthy cigarette smokers. As 99mTc-se... Read More about Does P-glycoprotein have a role in the lung clearances of inhaled 99mTc-sestamibi and 99mTc-tetrofosmin?.