Skip to main content

Research Repository

Advanced Search

Outputs (179)

Malignant breast masses-conspicuity analysis in motionsimulated mammograms (2018)
Presentation / Conference
mammograms. Poster presented at The 2018 European Congress of Radiology (ECR), Vienna

The conspicuity of a mass represents a ratio between the contrast of a mass and its surrounding complexity. Measuring the conspicuity of lesions attempts to characterise the visibility of a lesion in terms of the imaging systems diagnostic capabiliti... Read More about Malignant breast masses-conspicuity analysis in motionsimulated mammograms.

The impact of hoist sling materials on interface pressure whilst sitting in healthy volunteers and wheelchair users : a comparative study (2017)
Journal Article
Webb, J., Twiste, M., Walton, L., & Hogg, P. (2018). The impact of hoist sling materials on interface pressure whilst sitting in healthy volunteers and wheelchair users : a comparative study. Journal of Tissue Viability, 27(2), 90-94. https://doi.org/10.1016/j.jtv.2017.12.001

Aim of the study
To evaluate the effect of three sling fabrics on gluteal interface pressure whilst sitting in a population of wheelchair users and to compare these to data previously collected in a pilot study with a healthy population.
Material... Read More about The impact of hoist sling materials on interface pressure whilst sitting in healthy volunteers and wheelchair users : a comparative study.

A review of mammographic positioning image quality criteria for the craniocaudal projection (2017)
Journal Article
Sweeney, R.-J., Lewis, S., Hogg, P., & McEntee, M. (2017). A review of mammographic positioning image quality criteria for the craniocaudal projection. British Journal of Radiology, 91(1082), https://doi.org/10.1259/bjr.20170611

Detection of breast cancer is reliant on optimal breast positioning and the production of quality images. Two projections, the mediolateral (MLO) and craniocaudal (CC), are routinely performed. Determination of successful positioning and inclusion of... Read More about A review of mammographic positioning image quality criteria for the craniocaudal projection.

Challenges associated with x-ray imaging of stretcher-bound patients (2017)
Journal Article
Tugwell, J., England, A., Hogg, P., & Legg, J. (2017). Challenges associated with x-ray imaging of stretcher-bound patients. Radiologic technology, 89(2), 159-172

Patients often arrive at imaging departments on stretchers, and in certain circumstances they must remain on the stretcher for the imaging examination to reduce the likelihood of exacerbating injuries. Imaging stretcher-bound patients can be challeng... Read More about Challenges associated with x-ray imaging of stretcher-bound patients.

Mathematical modelling of radiation-induced cancer risk from breast screening by mammography (2017)
Journal Article
Ali, R., England, A., Mercer, C., Tootell, A., Walton, L., Schaake, W., & Hogg, P. (2017). Mathematical modelling of radiation-induced cancer risk from breast screening by mammography. European Journal of Radiology, 96, 98-103. https://doi.org/10.1016/j.ejrad.2017.10.003

Objectives: Establish a method to determine and convey lifetime radiation risk from FFDM screening.
Methods: Radiation risk from screening mammography was quantified using effective risk (number of radiation-induced cancer cases/million). For effec... Read More about Mathematical modelling of radiation-induced cancer risk from breast screening by mammography.

Intercountry analysis of breast density classification using visual grading (2017)
Journal Article
Damases, C., Hogg, P., & McEntee, M. (2017). Intercountry analysis of breast density classification using visual grading. British Journal of Radiology, 90(1076), 20170064. https://doi.org/10.1259/bjr.20170064

OBJECTIVE: Disagreement in mammographic breast density (MBD) assessment can impact breast cancer risk stratification, choices of further breast cancer screening intervals and pathways. This study examines whether intercountry MBD expectations and ass... Read More about Intercountry analysis of breast density classification using visual grading.

Research informed teaching experience in diagnostic radiography : the perspectives of academic tutors and clinical placement educators (2017)
Journal Article
Higgins, R., Hogg, P., & Robinson, L. (2017). Research informed teaching experience in diagnostic radiography : the perspectives of academic tutors and clinical placement educators. Journal of Medical Imaging and Radiation Sciences, 48(3), 226-232. https://doi.org/10.1016/j.jmir.2017.06.002

Introduction: This small scale qualitative research study investigated the perceptions by both academic tutors and clinical placement educators of integrating the research-informed teaching experience (RiTe) within an undergraduate radiography curric... Read More about Research informed teaching experience in diagnostic radiography : the perspectives of academic tutors and clinical placement educators.

Achieving success in clinically based research : the importance of mentoring (2017)
Journal Article
Ward, E., Brown, E., Hogg, P., Halkett, G., & Hargrave, C. (2017). Achieving success in clinically based research : the importance of mentoring. Journal of Medical Radiation Sciences, 64(4), 315-320. https://doi.org/10.1002/jmrs.234

Within the professions of radiation therapy and medical imaging, clinician led research activity is becoming more prevalent. However, more is needed. A key component of continuing to develop professional groups who are both research active and produc... Read More about Achieving success in clinically based research : the importance of mentoring.

The impact of simulated motion blur on lesion detection performance in full field digital mammography (2017)
Journal Article
Abdullah, A., Thompson, J., Kelly, J., Mercer, C., Aspin, R., & Hogg, P. (2017). The impact of simulated motion blur on lesion detection performance in full field digital mammography. British Journal of Radiology, 90(1075), https://doi.org/10.1259/bjr.20160871

Objective: Motion blur is a known phenomenon in full-field digital mammography, but the impact on lesion detection is unknown. This is the first study to investigate detection performance with varying magnitudes of simulated motion blur.
Method: S... Read More about The impact of simulated motion blur on lesion detection performance in full field digital mammography.

Inter country analysis of breast density classification using visual grading. Analysis of mammographic breast density using visual grading (2017)
Journal Article
Damases, C., Hogg, P., & McEntee, M. (2017). Inter country analysis of breast density classification using visual grading. Analysis of mammographic breast density using visual grading. British Journal of Radiology, 90(1076), https://doi.org/10.1259/bjr.20170064

Purpose: Disagreement in mammographic breast density (MBD) assessment can impact breast cancer risk stratification, choices of further breast cancer screening intervals and pathways. This study examines whether inter-country MBD expectations and asse... Read More about Inter country analysis of breast density classification using visual grading. Analysis of mammographic breast density using visual grading.