Impact testing is undertaken to quantify the shock absorption characteristics of footwear. The current widely reported mechanical testing method mimics the heel impact in running and therefore applies excessive energy to walking footwear. The purpose of this study was to modify the ASTM protocol F1614 (Procedure A) to better represent walking gait. This was achieved by collecting kinematic and kinetic data while participants walked in four different styles of walking footwear (trainer, oxford shoe, flip-flop and triple-density sandal). The quantified heel-velocity and effective mass at ground-impact were then replicated in a mechanical protocol. The kinematic data identified different impact characteristics in the footwear styles. Significantly faster heel velocity towards the floor was recorded walking in the toe-post sandals (flip-flop and triple-density sandal) compared with other conditions (e.g. flip-flop: 0.36 ± 0.05 m s−1 versus trainer: 0.18 ± 0.06 m s−1). The mechanical protocol was adapted by altering the mass and drop height specific to the data captured for each shoe (e.g. flip-flop: drop height 7 mm, mass 16.2 kg). As expected, the adapted mechanical protocol produced significantly lower peak force and accelerometer values than the ASTM protocol (p < .001). The mean difference between the human and adapted protocol was 12.7 ± 17.5% (p < .001) for peak acceleration and 25.2 ± 17.7% (p = .786) for peak force. This paper demonstrates that altered mechanical test protocols can more closely replicate loading on the lower limb in walking. This therefore suggests that testing of material properties of footbeds not only needs to be gait style specific (e.g. running versus walking), but also footwear style specific.
Price, C., Cooper, G., Graham-Smith, P., & Jones, R. (2014). A mechanical protocol to replicate impact in walking footwear. Gait & Posture, 40(1), 26-31. https://doi.org/10.1016/j.gaitpost.2014.01.014
Journal Article Type | Article |
---|---|
Acceptance Date | Jan 17, 2014 |
Online Publication Date | Feb 2, 2014 |
Publication Date | May 1, 2014 |
Deposit Date | May 7, 2014 |
Journal | Gait & Posture |
Print ISSN | 0966-6362 |
Publisher | Elsevier |
Peer Reviewed | Peer Reviewed |
Volume | 40 |
Issue | 1 |
Pages | 26-31 |
DOI | https://doi.org/10.1016/j.gaitpost.2014.01.014 |
Keywords | Shock; Footwear; Heel-strike transient; Accelerometer; Impact testing |
Publisher URL | http://dx.doi.org/10.1016/j.gaitpost.2014.01.014 |
About USIR
Administrator e-mail: library-research@salford.ac.uk
This application uses the following open-source libraries:
Apache License Version 2.0 (http://www.apache.org/licenses/)
Apache License Version 2.0 (http://www.apache.org/licenses/)
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search